Instructions for the installer
2. INSTALLATION
2.1 Electrical connection
Check that mains voltage and power cable ratings are as per the indications provided on the label attached to the oven door frame.
This label must never be removed.
It is obligatory for the electrical system to be grounded according to the methods required by safety rules.
If a plug and socket connection is being used make sure that the plug and socket are compatible. Avoid use of adapters and shunts as these could cause overheating and risk of burns.
If a fixed connection is being used fit power line with an omnipolar circuit breaker with a contact opening gap equal to or greater than 3 mm in an easily accessible position in proximity to the oven.
For operation on
The cable end to be connected to the appliance must be provided with an ground wire
The manufacturer declines all responsibility for damage to persons or things caused by
26