Page 8

V. CARE & MAINTENANCE (contd)

VI. OTHER

V. g - REPLACING THE LIGHT BULB:

All Traulsen R & A Series models are supplied with incandecent lighting unless optional fluorescent lighting was ordered (except for sliding glass door models for which fluorescent lights are supplied standard).

The bulb is a 115 volt/40 watt, T-612intermediate clear refrigerator lamp. It is mounted at the top front of the cabinet at the center, and is located behind a plastic light cover on refrigerator and freezer model.

Heated units (RHF/AHF/RIH/AIH/RDH/ADH/RIDH/AIDH) are equipped with a similar type bulb, however this is shatterproof because these models do not include a plastic light cover.

To replace the bulb, first remove the light cover (if so equipped). This can be accomplished by squeezing it together on both sides until it comes free. Replace the light bulb, then squeeze both sides of the light cover together and replace in its original position.

VI. a - SERVICE INFORMATION:

Before calling for service, please check the following:

Is the electrical cord plugged in?

Is the fuse OK or circuit breaker on?

Is the power switch ON?

If after checking the above items and the unit is still not operating properly, please contact an authorized Traulsen service agent. A complete list of authorized service agents was provided along with your Traulsen unit. If you cannot locate this, you may also obtain the name of a service agent from the Service/Contact page of our website: www.traulsen.com.

If service is not satisfactory, please contact our in-house service department at:

Traulsen

4401 Blue Mound Road Fort Worth, TX 76106 (800) 825-8220

Traulsen reserves the right to change specifications or discontinue models without notice.

VI. b - SPARE PARTS:

Spare or replacement parts may be obtained through a parts supplier or one of our authorized service agents. A complete list of authorized service agents accompanies this manual and is also posted on our companys official website @ www.traulsen.com.

VI. c - WARRANTY REGISTRATION:

For your convenience, the warranties on your new Traulsen unit may be registered with us by one of two methods. Completing the enclosed warranty card (shipped with the unit).

-7-

Image 8
Contents Form Number TR35743 REV /04 Table of Contents Serial TAGIII. Installation III. InstallationStable Before Installing Legs or Casters II. Receipt InspectionSealing Base of ROLL-IN Models III. Installation Care & Maintenance IV. OperationEfficiently and use less energy First consulting the factoryCare & Maintenance cont’d Replacing the GasketsVI. Other Alarms See the following pages for explanations VII. The INTELA-TRAULControl SystemVII. a Alarm Explanations VII. INTELA-TRAULPossible Causes for Refrigerator & Freezer Models Possible CausesAlarm Cancel Button Defrost Icon LED for FDigit RED LED Display LEDVII. e Notes to the User VII. g Customer Service Parameters VII. h Adjusting the Thermostat SET Point HighVII. i Adjusting the Thermostat SET Point LOW VII. j Changing the Temperature ScaleVII. k Setting the 24-HOUR Clock VII. l Setting the Date VII. m Setting Daylight Savings TimeDefrost Icon VII. n Starting a Manual Defrost CycleVII. o Setting the Defrost Lockouts SampleVII. p Adjusting the Door Perimeter Heaters VII. q Adjusting the Room Temperature OffsetVII. r Setting the Audible Alarm Style VII. s Viewing Sensor TemperaturesVII. u HOT Food UNITS, Temperature Adjustment VII. u HOT Food UNITS, Turning the Unit OFF/ONVIII. Trouble Shooting Guide Find Your Problem Here RemedyXI. Spare Parts List Part DescriptionXII. b Stainless STEEL, HOW IT Works XII. Stainless Steel OverviewXIII. Care of Stainless Steel Cont’d XIV. Corrosion RemediesXV. Warranty Information Standard Domestic WarrantyXVI. Index INTELA-TRAULHours of Operation