V. CARE & MAINTENANCE (cont’d) | VI. OTHER |
V. g - REPLACING THE LIGHT BULB:
All Traulsen R & A Series models are supplied with incandecent lighting unless optional fluorescent lighting was ordered (except for sliding glass door models for which fluorescent lights are supplied standard).
The bulb is a 115 volt/40 watt,
Heated units (RHF/AHF/RIH/AIH/RDH/ADH/RIDH/AIDH) are equipped with a similar type bulb, however this is shatterproof because these models do not include a plastic light cover.
To replace the bulb, first remove the light cover (if so equipped). This can be accomplished by squeezing it together on both sides until it comes free. Replace the light bulb, then squeeze both sides of the light cover together and replace in its original position.
VI. a - SERVICE INFORMATION:
Before calling for service, please check the following:
Is the electrical cord plugged in?
Is the fuse OK or circuit breaker on?
Is the power switch “ON”?
If after checking the above items and the unit is still not operating properly, please contact an authorized Traulsen service agent. A complete list of authorized service agents was provided along with your Traulsen unit. If you cannot locate this, you may also obtain the name of a service agent from the Service/Contact page of our website: www.traulsen.com.
If service is not satisfactory, please contact our
Traulsen
4401 Blue Mound Road Fort Worth, TX 76106 (800)
Traulsen reserves the right to change specifications or discontinue models without notice.
VI. b - SPARE PARTS:
Spare or replacement parts may be obtained through a parts supplier or one of our authorized service agents. A complete list of authorized service agents accompanies this manual and is also posted on our company’s official website @ www.traulsen.com.
VI. c - WARRANTY REGISTRATION: