VII. The INTELA-TRAUL® Control System
Your new Traulsen Refrigerator, Freezer or Hot Food cabinet is equipped with a
VII. a -
•Eliminates defrost time clock (refrigerator and freezer models only).
•Defrost cycle can be quickly adjusted to suit individual location and use.
•Must be set at
•Will automatically update for Daylight Savings Time.
2- Water Resistant Housing - The face of the control is water resistant to provide for protection during cleaning.
3- Parameter/Service Levels
•See “Customer / Service Parameters” on Page 11.
4- Defrost Lockouts - See “Setting Defrost Lockouts” on page 17 (refrigerator and freezer models only).
•Customers can set up to 4 different defrost lockout periods. The lockout prevents the unit from going into a defrost cycle during peak kitchen use. Note: The
5- Data Storage - The control comes equipped with 72 hours worth of data storage capability including:
•Records cabinet air temperatures every 6 minutes, needed to document “Due Diligence” in accordance with HAACP standards.
•Records alarm events.
•Records diagnostic test of each sensor every 24 hours.
•Records failed security attempts.
•Records door open cycles.
•Records defrost cycles (refrigerator and freezer models only).
Note: The
6- Communication Ability - An RS485 port port is available as a means of retrieving information from the stored data.
7-
8- Alarms (See the following pages for explanations) |
|
| |
• | High Cabinet Air Temperature | • | System Leak (refrigerator, freezer & |
• | Low Cabinet Air Temperature | • | Door Open** |
• | Loss Of Power | • Clean Condenser (refrigerator and freezer models only)* | |
• | Sensor Failure |
| * Not Available On Remote Models |
|
|
|
** Not Available On