Important!

Whenever the ice machine is taken out of operation during the winter months, the procedure below must be performed. Failure to do so may cause serious damage and will void all warranties.

1.Turn off water to machine.

2.Make sure all ice is off of the evaporator(s). If ice is being made, initiate harvest or wait for cycle completion.

3.Place the ICE/OFF/WASH switch to the “OFF” position. The switch is located in the control box.

4.Disconnect the tubing between the water pump discharge and water distribution tube.

5.Drain the water system completely.

6.On water cooled machines, hold the water regulating valve open by prying upward on the water valve spring with a screwdriver while using compressed air to blow all the water out of the condenser.

7.Remove all of the ice in the storage bin and discard.

Page 19

Image 24
Contents Publication Number Revision Date September Revision AInstallation, Start-upand Maintenance Manual Nordic Ice MakerPage How To Use This Manual ForwardKeep this manual for future reference PageTable of Contents Freight Claim ProcedureInstallation Guidelines Start-UpProcedureFreight Claim Procedure Freight Claims Important Inspect PromptlyVisible Loss or Damage Concealed Loss or DamageModel and Serial Number Format Sample Data PlateModel Number Serial NumberInstallation Guidelines Installation Guidelines Electrical SpecificationsAdjustments Ambient Operating TemperaturesInstallation Guidelines Attach the ice machine to the bin ordispenser with the provided PageRemote Condenser Installation Air FlowRemote Condenser Guidelines Installation GuidelinesRemote Condenser Guidelines PageON-OFF-WASHSwitch is located in the control box Remove the grill screws to access the control boxElectrical and Plumbing Requirements PageON-OFF-WASHSwitch is located in the control box Remove the grill screws to access the control boxElectrical and Plumbing Requirements PageElectrical and Plumbing Requirements Includes 50Hz. UnitsPage Includes 50Hz. And 3 Phase Units Electrical and Plumbing RequirementsPage Includes 50Hz. and 3 Phase Units Electrical and Plumbing RequirementsPage Electrical and Plumbing Requirements PageElectrical and Plumbing Requirements PageHow the CCM Ice Machine Works How the Ice Machine WorksPage Start-UpProcedure Start-UpProcedure Bridge Thickness and Timer AdjustmentPage Start-UpProcedure Bin Control Operation Bin Control AdjustmentUndercounter Models PageGeneral Maintenance General Maintenance ProcedurePage Cleaning Procedure Ice Machine Cleaning and Sanitizing InstructionsPage Cabinet Care Cleaning stainless steel Cleaning ActivityCleaning Agent Method of ApplicationWinterizing Procedure Winterizing Procedures PageService History Service HistoryPage