Cornelius CCM CCU manual Start-UpProcedure Bin Control Operation, Bin Control Adjustment, Page

Page 20
Start-Up Procedure
Thermal -well
Thermostatic
Bin Control

Start-Up Procedure

Bin Control Operation

The bin control is used to shut the machine off when the bin fills with ice. The bin control must be checked upon installation or initial start-up and when performing maintenance.

There is one bin switch for each evaporator. The actuator arm of the bin switch comes in contact with the splash curtain. When the bin is full of ice, the splash curtain is held open when ice drops off of the evaporator. This releases the pressure of the bin switch actuator arm allowing the switch to open.

Single evaporator machines: (Including the CCM1530) If the bin switch opens during freeze or the first part of harvest, relay 2 bypasses the bin switch and the machine will continue running. If the bin switch is opened during harvest when the cam switch is lifted onto the high part of the cam, the machine will shut off. When the bin switch closes again, the machine will restart.

Dual evaporator machines: If either bin switch opens during the freeze cycle, the machine will shut off. Relay 1 and relay 2 will bypass the bin switches during defrost. If either bin switch is open when the machine returns to the freeze cycle, the machine will shut off.

Undercounter machines: A thermostatic bin control is used on the undercounter

Bin Switch

Adjustment

models. The bin thermostat is located in the control box with a capillary tube,

Nuts

which is in a brass thermo-well mounted to the water trough. When ice comes in

 

contact with the capillary tube thermo-well, the bin thermostat opens and the

 

machine will shut off.

 

Bin Control Adjustment

All Models (Except Undercounter Models): Check the bin switch for proper adjustment by swinging the bottom of the curtain away from the evaporator. Slowly bring the curtain towards the evaporator. The switch should close when the bottom edge of the curtain is even with the outer edge of the water trough. Adjust the switch by loosening the nuts that hold the switch in place. Move the switch to the proper position and retighten the nuts. Recheck the adjustment.

Undercounter Models

Turn the machine to the ICE or WASH position. Hold ice against the brass thermal-well mounted to the water trough making sure the ice is in contact with at least 6 inches (15 cm) of the thermal-well. The machine should shut off in

approximately 1 minute. Remove the ice. The machine should restart in approximately 3 minutes. If a major adjustment is

required, turn the adjustment screw counterclockwise (warmer) until it stops then turn the adjustment screw clockwise (colder) 1/8 of a turn. This should put the control close to the proper adjustment, recheck and make a minor adjustment if needed. If a minor adjustment is required, turn the adjustment screw clockwise (colder) or counterclockwise (warmer).

Splash Curtain

Evaporator

The bin switch contacts must be closed when the bottom edge of the curtain is flush with the edge of the water trough

Page 15

Image 20
Contents Publication Number Revision Date September Revision AInstallation, Start-upand Maintenance Manual Nordic Ice MakerPage How To Use This Manual ForwardKeep this manual for future reference PageTable of Contents Freight Claim ProcedureInstallation Guidelines Start-UpProcedureFreight Claim Procedure Freight Claims Important Inspect PromptlyVisible Loss or Damage Concealed Loss or DamageModel and Serial Number Format Sample Data PlateModel Number Serial NumberInstallation Guidelines Installation Guidelines Electrical SpecificationsAdjustments Ambient Operating TemperaturesInstallation Guidelines Attach the ice machine to the bin ordispenser with the provided PageRemote Condenser Installation Air FlowRemote Condenser Guidelines Installation GuidelinesRemote Condenser Guidelines PageON-OFF-WASHSwitch is located in the control box Remove the grill screws to access the control boxElectrical and Plumbing Requirements PageON-OFF-WASHSwitch is located in the control box Remove the grill screws to access the control boxElectrical and Plumbing Requirements PagePage Electrical and Plumbing RequirementsIncludes 50Hz. Units Page Includes 50Hz. And 3 Phase UnitsElectrical and Plumbing Requirements Page Includes 50Hz. and 3 Phase UnitsElectrical and Plumbing Requirements Electrical and Plumbing Requirements PageElectrical and Plumbing Requirements PagePage How the CCM Ice Machine WorksHow the Ice Machine Works Page Start-UpProcedure Start-UpProcedureBridge Thickness and Timer Adjustment Start-UpProcedure Bin Control Operation Bin Control AdjustmentUndercounter Models PagePage General MaintenanceGeneral Maintenance Procedure Page Cleaning ProcedureIce Machine Cleaning and Sanitizing Instructions Cabinet Care Cleaning stainless steel Cleaning ActivityCleaning Agent Method of ApplicationWinterizing Procedure Winterizing Procedures PagePage Service HistoryService History