![](/images/new-backgrounds/1265769/265769113x1.webp)
INTEGRUS Installation and User Instructions Integrus Charging Units | en 51 |
|
|
5.2Wall mounting the charging cabinet
LBB 4560/50 is suitable for either
It can be
Warning: To comply with UL and CSA regulations, the charging cabinets must be mounted in such a way that they can be easily removed by hand in case of emergency.
Figure 5.2 Charging cabinet mounting dimensions
5.3 Charging procedure
Ensure that the charging unit is connected to the mains and that it is switched on. Place the receivers firmly in the charging compartments. The charging indicator LEDs on all receivers should illuminate. These LEDs indicate the charging status of each receiver:
LED colour | Charging status |
|
|
Green | Charging completed. |
|
|
Red | Charging in progress. |
|
|
Red blinking | Error status. See chapter 6, |
| |
|
|
Off | Charger switched off or receiver not |
| properly inserted. |
|
|
Notes:
•It is preferred to switch on the charg- ing unit before inserting the receivers. Receivers can be inserted or removed without damage while the charging unit is switched on.
•Charge the battery pack to full capaci- ty before using them for the first time.
•The charger always applies fast charge during the first 10 minutes after inserting a receiver. Inserting the receiver multiple times with a fully charged battery pack should therefore be avoided, as this will damage the battery pack.
•Continuously charging the receiver will not damage the receiver or bat- tery pack. Receivers can therefore safely be left in their charging posi- tions when they are not used.
•When the rechargeable battery pack is used, it is advisable to check regu- larly after three years that the batter- ies are not leaking. If there is any sign of leakage or corrosion, replace the battery pack. Ensure that only the bat- tery pack LBB 4550/00 is used. The battery pack has to be replaced at least every five years.
Bosch Security Systems