3Integrus Radiators
3.1Medium and High Power Radiators
3.1.1 Description
These units accept the carrier signals generated by the transmitter and emit
The LBB 4511/00 has an
32 Wpp. Both have an automatic mains power voltage selection and are switched on automatically when the transmitter is switched on.
The attenuation of the signal by the cable is equalised automatically by the radiator. When the radiator is sup- plied with power and the transmitter is switched on, the radiator initialises the equalisation. The red LEDs flash for a brief period of time to indicate that the ini- tialisation is in progress.
When not receiving carrier waves, the radiators switch to standby mode. There is also a temperature protec- tion mode which automatically switches the radiators from full to half power or from half power to
1 |
|
| |
| Loop - Through inputs |
2 | Do not |
terminate | |
| Output power |
3 | High |
Low | |
| Delay compensation |
| X10 |
4 |
|
| X1 |
Figure 3.1 LBB 4511/00 and LBB4512/00 Radiators
(Back view)
5 | 6 | 5 | 6 |
Figure 3.2 LBB 4512/00 High Power Radiator (Front view)
Figure 3.1 and 3.2
1.Mains input - Male Euro mains connector. The radiators have automatic mains voltage selection.
2.IR signal
3.Output power selection switch - The radiators can be switched between full- and
4.Delay compensation switches - Two
5.Amber indicator LEDs - Give an indication of the radiator status.
6.Red indicator LEDs - Give an indication of the radiator status.
Note: The indicator LEDs are positioned
behind the
are only visible when ON.
Bosch Security Systems