Caution: Turn the delay switches carefully to a new position until you feel that it clicks into position, to prevent that a switch is positioned between two numbers, which would result in a wrong delay setting.

Note: When a master-slave configuration is used for rooms which are always sepa- rated, the delay switch positions can be determined per system and the delay caused by transmission from master to slave transmitter can be ignored.

Figure 1.28, table 1.1, table 1.3 and table 1.4 illustrate the calculation of the extra master-slave signal delay.

Table 1.3 Calculation of the master-to-slave signal delays

 

20m

 

30m

R2

 

R1

 

 

 

 

20m

 

R3

 

Tx1

R5

20m

R4

30m

R7

20m

R6

50m

30m

 

R8

 

Tx2

 

 

 

20m

R10

 

R9

 

 

20m

 

30m

Figure 1.28 System with master and slave transmitter in

multi purpose room

Cable length

 

Cable

 

 

Cable

 

 

Signal delay

 

 

Master-to-slave

 

master-slave

 

signal delay

 

signal delay

 

 

slave transmitter

 

 

signal delay [ns]

 

transmitter [m]

 

per meter [ns/m]

 

[ns]

 

 

 

[ns]

 

 

 

 

 

50

 

5.6

 

 

50 x 5.6 = 280

 

 

33

 

 

280 + 33 = 313

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1.4

 

Calculation of the delay switch positions of a system with two transmitters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Radiator

 

Transmitter

Master-to-

 

Cable signal

 

Total signal

 

Signal delay

Delay switch

 

number

 

 

 

slave signal

 

delay [ns]

 

delay [ns]

 

difference

 

 

position

 

1

 

Master

0

 

168

 

0+168 = 168

 

593-168 = 425

425/33 = 12.88 = 13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Master

0

 

280

 

0+280

= 280

 

593-280 = 313

 

313/33 = 9.48 =

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

Master

0

 

112

 

0+112 = 112

 

593-112 = 481

 

481/33 = 14.58 = 15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

Master

0

 

168

 

0+168 = 168

 

593-168 = 425

425/33 = 12.88 = 13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Master

0

 

280

 

0+280

= 280

 

593-280 = 313

 

313/33 = 9.48 =

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

Slave

313

 

168

 

313+168 = 481

 

593-481 = 112

 

112/33 = 3.39 =

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

Slave

313

 

280

 

313+280

= 593

 

593-593 =

0

0/33 =

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

Slave

313

 

112

 

313+112

= 425

 

593-425 = 168

168/33 = 5.09 =

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

Slave

313

 

168

 

313+168 = 481

 

593-481 = 112

 

112/33 = 3.39 =

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

Slave

313

 

280

 

313+280

= 593

 

593-593 =

0

0/33 =

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 