For
■Recirculating Kit Part Number W10294734 for
■6" (15.2 cm) round metal vent duct. Length required is determined by ceiling height.
Parts supplied
Remove parts from packages. Check that all parts are included.
■Hood ventilator assembly with vent transition, back draft damper, and light bulb installed.
■Canopy glass
■2 - Retainer brackets for hood glass canopy.
■2 - Rubber seals (canopy glass)
■Metal grease filter
■68 - 4 x 8 mm screws
■4 - 5 x 45 mm screws
■T10 Torx® adapter
■T20® Torx®† adapter
■4 - Vent covers
■4 - Plastic vent clips
■Mounting template
■Upper horizontal support bracket
■Horizontal support
■8 - Vertical supports
■2- Vent cover supports
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.
Product Dimensions
13³⁄₁₆" (33.6 cm)
12¼" (31.0 cm)
*29³⁄₄" | **29³⁄₄" |
(75.6 cm) | (75.6 cm) |
min. min.
*44¹³⁄₁₆" *49¹³⁄₁₆"
(113.8 cm) (126.5 cm)
max. max.
3¹⁄₂"
(8.9 cm)
25³⁄₁₆" |
|
(64.0 cm) | 36" (91.4 cm) |
|
*Vented installations only
Installation Dimensions
LocationRequirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical Requirements” section.
Because of the size and weight of this island hood, the chimney support must be securely attached to the ceiling.
■For plaster or drywall ceilings, the chimney support must be attached to joists. If this is not possible, you must build a support structure behind the plaster or drywall. The support structure must be able to support 80 lbs (36.6 kg).
The range hood is factory set for venting through the roof or wall.
For
All openings in ceiling and wall where range hood will be installed must be sealed.
B
C D
A
A. Countertop height
B. Hood height from ceiling to bottom of the range hood filter surface:
C. Hood height: 24" (61.0 cm) min. from electric cooking surface, 27" (68.6 cm) min. from gas cooking surface, suggested 36" (91.4 cm) max.
D. Ceiling height
IMPORTANT:
Minimum distance “C”: 24" (61.0 cm) from electric cooking surface, 27" (68.6 cm) from gas cooking surface Suggested maximum distance “C”: 36" (91.4 cm)
†®TORX and T20 are registered trademarks of Saturn Fasteners, Inc.