Whirlpool GXI6536DXS LocationRequirements, Parts supplied, For Mobile Home Installations

Page 4

For non-vented (recirculating) installations, you will also need:

Recirculating Kit Part Number W10294734 for non-vented (recirculating) installations only. See “Assistance or Service” section to order.

6" (15.2 cm) round metal vent duct. Length required is determined by ceiling height.

Parts supplied

Remove parts from packages. Check that all parts are included.

Hood ventilator assembly with vent transition, back draft damper, and light bulb installed.

Canopy glass

2 - Retainer brackets for hood glass canopy.

2 - Rubber seals (canopy glass)

Metal grease filter

68 - 4 x 8 mm screws

4 - 5 x 45 mm screws

T10 Torx® adapter

T20® Torx®† adapter

4 - Vent covers

4 - Plastic vent clips

Mounting template

Upper horizontal support bracket

Horizontal support

8 - Vertical supports

2- Vent cover supports

For Mobile Home Installations

The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.

Product Dimensions

13³⁄₁₆" (33.6 cm)

12¼" (31.0 cm)

*29³⁄₄"

**29³⁄₄"

(75.6 cm)

(75.6 cm)

min. min.

*44¹³⁄₁₆" *49¹³⁄₁₆"

(113.8 cm) (126.5 cm)

max. max.

3¹⁄₂"

(8.9 cm)

25³⁄₁₆"

 

(64.0 cm)

36" (91.4 cm)

 

*Vented installations only

**Non-vented (recirculating) installations only

Installation Dimensions

LocationRequirements

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the left filter on the rear wall of the vent hood.

Canopy hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical Requirements” section.

Because of the size and weight of this island hood, the chimney support must be securely attached to the ceiling.

For plaster or drywall ceilings, the chimney support must be attached to joists. If this is not possible, you must build a support structure behind the plaster or drywall. The support structure must be able to support 80 lbs (36.6 kg).

The range hood is factory set for venting through the roof or wall.

For non-vented (recirculating) Installation see “Non-vented (recirculating) Installation” in “Install Range Hood” section. Recirculating Kit Part Number W10294734 is available from your dealer or an authorized parts distributor.

All openings in ceiling and wall where range hood will be installed must be sealed.

B

C D

A

A. Countertop height

B. Hood height from ceiling to bottom of the range hood filter surface: D-A-C=B

C. Hood height: 24" (61.0 cm) min. from electric cooking surface, 27" (68.6 cm) min. from gas cooking surface, suggested 36" (91.4 cm) max.

D. Ceiling height

IMPORTANT:

Minimum distance “C”: 24" (61.0 cm) from electric cooking surface, 27" (68.6 cm) from gas cooking surface Suggested maximum distance “C”: 36" (91.4 cm)

†®TORX and T20 are registered trademarks of Saturn Fasteners, Inc.

4

Image 4
Contents 36 91.4 CM ISLAND-MOUNT Canopy Range Hood Range Hood Safety Table of ContentsInstallation Requirements For vented installations, you will also needTools andParts Tools neededFor Mobile Home Installations Product DimensionsInstallation Dimensions LocationRequirementsCold Weather Installations For Non-Vented recirculating InstallationsVentingRequirements Makeup AirInstallation Instructions Electrical RequirementsPrepareLocation Calculating Vent System LengthAssembleRangeHood Range Hood Mounting Screws InstallationComplete Preparation Install RangeHood Non-Vented recirculating InstallationRange Hood Installation MakeElectrical ConnectionInstall DuctCovers CompleteInstallation Range Hood USERangeHoodControls Operating the lightCleaning Non-Vented recirculating Installation FiltersRange Hood Care Exterior SurfacesWiring Diagram Assistance or Service AccessoriesIntheU.S.A InCanadaWhirlpool Corporation Major Appliance Warranty This limited warranty does not coverSécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Exigences d’emplacement Exigences DinstallationOutils etpièces Dimensions d’installation Dimensions du produitExigencesconcernantlévacuation Installations dans une région à climat froid Installation sans décharge à lextérieur recyclageAir dappoint Calcul de la longueur effective du circuit dévacuationInstructions D’INSTALLATION PréparationdelemplacementInstallation des vis de montage de la hotte SpécificationsélectriquesAssemblagedelahotte Achever la préparationInstallationdela hotte Installation sans décharge à l’extérieur recyclageInstallation de la hotte RaccordementélectriqueInstallationdes cache-conduits Acheverl’installation CommandesdelahottedecuisinièrePour faire fonctionner la lampe Utilisation du ventilateurEntretien DE LA Hotte NettoyageSchéma DE Câblage Assistance OU Service AccessoiresGarantie DES Gros Appareils Ménagers Whirlpool Corporation AuCanadaW10292168D