5.Attach the horizontal support (B) using 8 - 4 x 8 mm screws.
B
A A
C C
A. Vertical supports
B. Horizontal support
C. Notched end
6.Attach a second set of vertical supports (A) and set the vertical height (B). See “Installation Dimensions” in the “Location Requirements” section to help determine the desired dimension for vertical height “B.”
A A
B
A. Vertical supports
B. Vertical height
Install RangeHood
Non-Vented (recirculating) Installation
1.Attach the air deflector to the upper horizontal support using 4 mounting screws.
B
A
B
A.Deflector
B.Mounting screws
2.Measure the length of 6" (15.2 cm) duct needed to connect the transition to the deflector.
NOTE: Vent should fit up inside the deflector 1" (2.5 cm) minimum.
3.Install vent between the transition and the deflector.
NOTE: To make vent installation easier, temporarily remove the deflector from the chimney support bracket and replace after vent section is in place.
4.Seal all connections with vent clamps. Continue with “Range Hood Installation” in this section.
Range Hood Installation
1.Using 2 or more people, lift the range hood assembly and attach it by snapping the vertical supports to the spring clips in the upper horizontal support bracket that is mounted to the ceiling.
2.Install 16 - 4 x 8 mm screws and tighten to secure.
A
A. Mounting screws
Connect Vent System
1.Install vent system.
2.Push duct over the exhaust outlet. Seal all connections with vent clamps.
3.Use caulk to seal all openings.
MakeElectrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Disconnect power.
2.Remove terminal box cover.
3.Remove the knockout in the terminal box cover and install a UL listed or CSA approved ¹⁄₂" strain relief.
A
B
A.Knockout
B.Terminal box cover
8