Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent piece

6" (15.2 cm) round

45° elbow

2.5 ft

 

(0.8 m)

 

 

90° elbow

5.0 ft

 

(1.5 m)

Maximum equivalent vent length is 35 ft (10.7 m).

Example Vent System

90 elbow

 

 

 

 

 

 

Wall cap

 

 

6 ft (1.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2ft

(0.6 m)

The following example falls within the maximum vent length of 35 ft (10.7 m).

1

- 90° elbow

= 5.0 ft (1.5 m)

1

- wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

 

 

System length

= 13 ft (3.9 m)

Electrical Requirements

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

If the house has aluminum wiring, follow the procedure below:

1.Connect a section of solid copper wire to the pigtail leads.

2.Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.

Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the range hood.

Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

INSTALLATION INSTRUCTIONS

PrepareLocation

Lay out the vent duct system before installing the range hood to determine the best routing for the vent duct.

It is recommended that the vent system be installed before the range hood is installed.

Before making cutouts, make sure there is proper clearance within the ceiling for exhaust vent.

Range hood is to be installed 24" (61.0 cm) min. for electric cooking surfaces, 27" (68.6 cm) min. for gas cooking surfaces, to a suggested maximum of 36" (91.4 cm) above the cooking surface.

Remove film from metal surfaces as needed prior to assembly.

Check your ceiling height and the range hood height maximum before you install your hood.

1.Disconnect power.

2.Determine which venting method to use: roof, wall or non- vented.

3.Select a flat surface for assembling the range hood. Place covering over that surface. Place two 3" (7.6 cm) high spacers (not included) onto the covered surface.

NOTE: Cover the spacers to avoid damage to the range hood surface.

WARNING

Excessive Weight Hazard

Use two or more people to move and install range hood.

Failure to do so can result in back or other injury.

4.Using 2 or more people, lift range hood onto covered spacers.

6

Image 6
Contents 36 91.4 CM ISLAND-MOUNT Canopy Range Hood Range Hood Safety Table of ContentsTools andParts Installation RequirementsFor vented installations, you will also need Tools neededInstallation Dimensions For Mobile Home InstallationsProduct Dimensions LocationRequirementsVentingRequirements Cold Weather InstallationsFor Non-Vented recirculating Installations Makeup AirPrepareLocation Installation InstructionsElectrical Requirements Calculating Vent System LengthRange Hood Mounting Screws Installation AssembleRangeHoodComplete Preparation Range Hood Installation Install RangeHoodNon-Vented recirculating Installation MakeElectrical ConnectionInstall DuctCovers RangeHoodControls CompleteInstallationRange Hood USE Operating the lightRange Hood Care CleaningNon-Vented recirculating Installation Filters Exterior SurfacesWiring Diagram IntheU.S.A Assistance or ServiceAccessories InCanadaWhirlpool Corporation Major Appliance Warranty This limited warranty does not coverSécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Exigences Dinstallation Exigences d’emplacementOutils etpièces Dimensions du produit Dimensions d’installationExigencesconcernantlévacuation Air dappoint Installations dans une région à climat froidInstallation sans décharge à lextérieur recyclage Calcul de la longueur effective du circuit dévacuationInstallation des vis de montage de la hotte Instructions D’INSTALLATIONPréparationdelemplacement SpécificationsélectriquesAssemblagedelahotte Achever la préparationInstallation de la hotte Installationdela hotteInstallation sans décharge à l’extérieur recyclage RaccordementélectriqueInstallationdes cache-conduits Pour faire fonctionner la lampe Acheverl’installationCommandesdelahottedecuisinière Utilisation du ventilateurEntretien DE LA Hotte NettoyageSchéma DE Câblage Garantie DES Gros Appareils Ménagers Whirlpool Corporation Assistance OU ServiceAccessoires AuCanadaW10292168D