Agilent Technologies 6633B, 6634B, 66332A, 6632B service manual Iout Iout + 2.3 mA

Page 22

2 - Verification and Performance Tests

Model Agilent 6634B

Report No _______________

Date __________________

Test Description

Minimum

Results*

Maximum

Measurement

 

Specs.

 

 

Specs.

 

Uncertainty

Constant Voltage Tests

 

 

 

 

 

 

 

 

 

 

 

 

Voltage Programming and Readback

 

 

 

 

 

 

 

 

 

 

 

 

Low Voltage (0V) Vout

− 50 mV

 

__________

+ 50 mV

 

2.1 ∝V

Front Panel Display Readback

Vout

12 mV

__________

Vout + 12 mV

2.1

 

 

 

 

 

 

 

V

High Voltage (Full Scale) Vout

99.9 V

 

__________

100.1 V

 

1.4 mV

Front Panel Display Readback

Vout − 42 mV

__________

Vout + 42 mV

1.4 mV

Load Effect

− 5 mV

 

__________

+ 5 mV

 

60 ∝V

Source Effect

− 1 mV

 

__________

+ 1 mV

 

60 ∝V

PARD (Ripple and Noise)

 

 

 

 

 

 

 

 

 

 

 

 

Peak-to-Peak

 

0 mV

 

__________

+ 3 mV

 

872 ∝V

RMS

 

0 mV

 

__________

+ 0.5 mV

50

 

 

 

 

 

 

 

 

 

 

 

V

Transient Response

 

 

 

 

 

 

 

 

 

 

 

 

Time in 100 ∝s

 

0 mV

 

__________

+ 100 mV

15 mV

Constant Current Tests

 

 

 

 

 

 

 

 

 

 

 

 

Current Programming and Readback

 

 

 

 

 

 

 

 

 

 

 

 

Low current (0A) Iout

− 0.5 mA

__________

+ 0.5 mA

15.1 ∝A

Readback Accuracy @ Iout

Iout

0.25 mA

__________

Iout + 0.25 mA

15.1

 

 

 

 

 

 

A

High Current (Full Scale) Iout

0.999 A

 

__________

1.001 A

 

128.8

 

 

 

 

 

A

Readback Accuracy @ Iout

Iout

 

 

2.3 mA

__________

Iout + 2.3 mA

128.8

 

 

 

 

 

 

 

A

Current Sink Readback

Isink − 2.9 mA

__________

Isink + 2.9 mA

128.8 ∝A

20 mA Range Current Readback

 

 

 

 

 

 

 

 

 

 

 

 

Readback Accuracy @ 0 A

− 2.5 ∝A

__________

+ 2.5 ∝A

0.1 ∝A

Readback Accuracy @ + 20 mA

Iout

22.5

__________

Iout + 22.5

1.7

 

 

 

A

 

A

 

A

Readback Accuracy @ − 20 mA

Iout

22.5

__________

Iout + 22.5

1.7

 

 

 

A

 

A

 

A

PARD (Current Ripple and Noise)

 

 

 

 

 

 

 

 

 

 

 

 

RMS

 

0 mA

 

__________

+ 2.0 mA

250 ∝A

Load Effect

− 1.0 mA

__________

+ 1.0 mA

1 ∝A

Source Effect

− 0.25 mA

__________

+ 0.25 mA

1 ∝A

* Enter your test results in this column

 

 

 

 

 

 

 

 

 

 

 

 

22

Image 22
Contents Agilent Part No Microfiche No September Warranty Information CertificationSafety Summary Before Applying PowerSafety Symbol Definitions Symbol DescriptionPrinting History Instrument IdentificationTable of Contents Introduction General Schematic Notes Backdating Initialization ROM UpgradeDisassembly Procedures Post-repair CalibrationPage Related Documents Safety ConsiderationsOrganization ChapterManual Revisions RevisionsElectrostatic Discharge Firmware RevisionsIntroduction Test Equipment RequiredTest Setup Measurement TechniquesElectronic Load Operation Verification TestsPerformance Tests Current-Monitoring ResistorVoltage Programming and Readback Accuracy CV SetupConstant Voltage CV Tests CV Load EffectCV Source Effect CV Noise PardConstant Current CC Tests Transient Recovery TimeCC Setup Current Programming and Readback AccuracyLow Range Current Readback Accuracy Current Sink -CC OperationCC Load and Line Regulation CC Load Effect CC Source EffectPerformance Test Equipment Form CC Noise PardPerformance Test Record Forms Iout + 0.25 mA Iout Iout + 4.3 mAIout Iout + 2.3 mA Troubleshooting Test Equipment Required for Troubleshooting Overall TroubleshootingFlow Charts Type Purpose Recommended ModelSheet 1. Main Flowchart Sheet 2. Main Flowchart Sheet 3. Main Flowchart Sheet 4. OV at Turn-On Sheet 5. OV at Turn-On Sheet 6. FS Indicated but Fuse OK Sheet 7. No Output Voltage Sheet 8. No Output Voltage Sheet 9 No Output Voltage Sheet 10. No Current Limit Sheet 11. Unit Does Not OV Sheet 12. High Output Voltage Self-Test Error Codes/Messages Specific Troubleshooting ProceduresPower-on Self-test Failures Error Code Description Probable CauseBias and Reference Voltages CV/CC Status Annunciators TroubleshootingBias and Rail Voltages Bias Test Point Common MeasurementJ307 Voltage Measurements Voltage Measurements at J307 A2 Interface to A1 Main boardDisabling Protection Features Manual Fan Speed ControlCalibration Password Inhibit Calibration SwitchPost-repair Calibration Initialization ROM UpgradeUpgrade Procedure Identifying the FirmwareRemote sense leads before attempting disassembly Disassembly ProceduresList of Required Tools A2 Interface Board, Removal and Replacement Cover, Removal and ReplacementFront Panel Assembly, Removal and Replacement T1 Power Transformer, Removal and Replacement S1 Line Switch, Removal and ReplacementA3 Front Panel Board, Removal and Replacement A1 Main Control BoardLine Voltage Wiring Transformer WiringPower Supply Interface signals Interface SignalsConnector Signal Description Primary Interface A3 Front Panel CircuitsA2 Interface Circuits Secondary InterfaceA2/A3 Block Diagram Power Circuits A1 Main Board CircuitsA1 Block Diagram Control Circuits Principles of Operation Page Chassis, Electrical Designator Model PartNumber Qty DescriptionChassis, Mechanical Designator Model Part Number Qty DescriptionMechanical Parts ldentification A1 Control Board PC Board Assembly Replaceable Parts Replaceable Parts Replaceable Parts Replaceable Parts Replaceable Parts Replaceable Parts Replaceable Parts Replaceable Parts Replaceable Parts Replaceable Parts Replaceable Parts A5 AC input/RFI Board Binding Post Option #020Relay Option #760 General Schematic Notes Model-dependent ComponentsDiagrams A1 Board Component Locations R434 825 R500 175 325 R435 R505 A1 Board Component Locations A4 and A6 Board Component Locations A1 Board schematic sheet A1 Board schematic sheet A1 Board schematic sheet A6 Relay Option Board schematic Index Index
Related manuals
Manual 103 pages 34 Kb Manual 83 pages 60.43 Kb

6632B, 6633B, 66332A, 6634B specifications

Agilent Technologies, a leader in electronic test and measurement solutions, offers a range of power supplies designed to meet various application needs. Notable models include the 6632B, 6634B, 66332A, 6633B, and 6612C. Each of these units provides unique features and technologies that cater to researchers, engineers, and technicians in the industry.

The Agilent 6632B is a single-output DC power supply that delivers up to 30V and 3A. It is known for its excellent load regulation and low noise, making it ideal for sensitive electronic testing. The model includes built-in voltage and current measurement capabilities, allowing users to monitor output conditions in real time. The 6632B is commonly used in laboratory environments, educational institutions, and manufacturing lines.

Moving to the 6634B, this model offers dual-output capabilities with a maximum output of 30V and 6A. This versatility enables simultaneous powering of two different devices or circuit sections. It also features parallel and series operation options, allowing users to create a custom power supply configuration for specific applications. With a programmable interface, the 6634B simplifies test automation, ensuring efficiency in extensive testing scenarios.

The Agilent 66332A stands out with its precision and high performance. This power supply provides three outputs—two programmable and one fixed—yielding flexible power configurations. Its intuitive user interface allows easy adjustment of voltage and current settings. The device is equipped with extensive protection features to safeguard both the power supply and the connected load against faults. It is an excellent choice for complex testing setups that require reliable power.

The 6633B model offers a high-performance power supply with dual outputs, similar to the 6634B but with enhanced specifications. It can provide up to 40V and 2A per channel, delivering precision for demanding applications. This model is particularly suited for industries focused on high-reliability applications, such as telecommunications and aerospace.

Lastly, the Agilent 6612C is a compact and lightweight power supply providing single-output up to 60V and 2A. This model is designed for simplicity and ease of use, making it an excellent choice for portable applications. The 6612C’s unique characteristics include a compact design and user-friendly controls, which facilitate operation in field settings.

In summary, Agilent Technologies’ power supply models—6632B, 6634B, 66332A, 6633B, and 6612C—offer an array of features that cater to a wide range of testing and research needs, ensuring reliable power delivery in various contexts.