Delfield 18600VD manual Versa Drawer Alarm

Page 16

Versa Drawer™ Refrigeration Units

Versa Drawer™ Alarm

Alarm

Meaning

Action

Alternate Action

 

 

 

 

Thaw Finished

Thaw cycle is complete and

Press corresponding drawer

 

 

unit is now in refrigeration

number to clear audio and

 

 

mode.

screen.

 

 

 

 

 

Chiller Finished

Chiller cycle has completed

Press corresponding drawer

 

 

and unit is now in

number to clear audio and

 

 

refrigeration mode.

screen.

 

 

 

 

 

Drawer Open

Drawer's been open for

Close drawer.

 

 

greater than set time.

 

 

 

 

 

 

Drawer temperature Out of

Drawer temperature's been

Press corresponding drawer

 

Range.

10 deg F above or below

number to clear audio and

 

 

setpoint for more than 15

screen.

 

 

minutes.

 

 

 

 

 

 

Loss of power

Power to unit was

Press i button to stop audio

 

 

interrupted.

alarm. Screen will change to

 

 

 

display time power failed, time

 

 

 

power was restored. Present

 

 

 

time. Press i button once more

 

 

 

to return to main screen

 

 

 

 

 

Drawer temperature

Temperature probe to drawer

Press i button to stop audio

 

probe(s) out of range.

box or evaporator is damage

alarm, screen will clear once

 

 

or temperature is out of

temperature drops into range

 

 

range.

or probe is repaired.

 

 

 

 

 

Condenser temperature

Temperature probe to

Press i button to stop audio

 

probe(s) out of range.

condenser is damaged or

alarm, screen will clear once

 

 

temperature is out of range.

temperature drops into range

 

 

 

or probe is repaired.

 

 

 

 

 

Compressor pressure

Pressure transducer

Press i button to stop audio

 

transducer(s) out of range.

damaged or pressure is

alarm. If unit is started in high

 

 

higher than 150 psi

ambient temperature alarm

 

 

 

will clear on pulldown. If

 

 

 

diagnostics shows "open" for

 

 

 

transducer, component must

 

 

 

be repaired.

 

 

 

 

 

Condenser fan(s) failure

Condenser fan has fail to pull

Press i button to stop audio

The screen will clear if power

 

down condenser outlet by

alarm. Alarm will remain on

to the unit is disconnected

 

1 degree over two minutes.

screen until service work is

and reconnected. If alarm

 

Condenser fan may not be

performed

keeps reoccurring after

 

operating or condenser coil

 

power has been removed

 

is dirty.

 

service is required.

 

 

 

 

Compressor(s) Failure

Compressor has failed to

Press i button to stop audio

The screen will clear if power

 

decrease suction pressure.

alarm. Alarm will remain on

to the unit is disconnected

 

 

screen until service work is

and reconnected. If alarm

 

 

performed

keeps reoccurring after

 

 

 

power has been removed

 

 

 

service is required.

 

 

 

 

Delfield · 980 S. Isabella Road, Mt. Pleasant, MI 48858 · (989) 773-7981 or (800) 733-8829 · Fax (989) 773-3210

15

Image 16
Contents Versa Drawer Refrigeration Units Important Warning and Safety Information Versa Drawer Refrigeration UnitsTable of Contents Receiving and Inspecting the Equipment Specifications 115V/60HzSerial Number Specifications 230-240V/50Hz Freestanding Models Volts Amps Plug ShipInstallation Operation Operating Controls MaintenanceDrawer Interface Control General Maintenance Cleaning the Condenser CoilStainless Steel Care and Cleaning Never use steel pads, wire brushes or scrapersPreventive Maintenance Gasket MaintenanceDrawer Refrigeration Schematic Drawer WiringUnits Drawer Wiring 7981 or$%4!,3 //!2$ Drawer Wiring Schematic //!2$Versa Drawer Alarm Labor of 1 Hour is Allowed to Replace Labor of 2 Hours to ReplaceLabor of 3 Hours to Replace Labor of 4 Hours to ReplaceStandard ONE Year Warranty ONE Year Parts and Labor Service Labor Contract Delfield CompanyDelfield Company Delfield Serial # Installation Model# Date General ConditionsThank you for choosing Delfield