Delfield 18600VD manual Installation

Page 6

Versa Drawer™ Refrigeration Units

INSTALLATION

ELECTRICAL CONNECTION

Never stand on the unit or its drawers! Doing so may result in bodily injury.

LOCATION

Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents, which can be up to 1,200 pounds(550kg). Reinforce the floor as necessary to provide for maximum loading.

The location should be selected so that power cords can be connected without any extension cords.

For the most efficient operation, be sure to provide good air circulation inside and out. Avoid hot corners and locations near stoves and ovens.

Direct exposure to excessive amounts of steam in machine compartment will result in control board failure.

INSIDE CABINET

Do not pack drawer so full that air cannot circulate. Load product level with top of pans and keep all food covered.

OUTSIDE CABINET

The front louvers must be kept 24"(60cm) clear of any obstructions. Proper operation of these models is dependent on air being able to flow freely through the front louvers. Side louvers must have 24"(60cm) of clearance for service access.

Any restriction of the proper airflow outlined above, total or partial, will void the warranty on the unit.

LEVELING

The unit must be level so the drain pan will drain properly, drawers will line up with frames and the cabinet will not be subject to undue strain.

ELECTRICAL CONNECTIONS AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

UNITS EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED WITH A THREE-PRONG GROUNDING PLUG. THIS PLUG MUST BE CONNECTED INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG FROM THIS PLUG.

A 7' (2.1 m) long grounded supply cord with three- pronged plug is provided with the standard units. Simply plug into a three-pronged wall outlet for proper grounding of the unit to begin operation.

Refer to the amperage data listed in the specifications, the serial number tag, your local code or the National Electrical Code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be installed for connection of the line cord or permanent connection to the unit.

Have the wall outlet checked by a qualified electrician to be sure a proper ground is present and that the outlet provides the correct voltage and required amperage to match the specifications. Do not use an adapter to connect to a two-pronged outlet. The three- pronged-outlet provides a ground connection that must be used to prevent a shock hazard.

Any power cord that is frayed or damaged should be replaced. When disconnecting the unit from the power source, do not pull on the cord. Firmly grip the plug and remove from outlet.

STABILIZING

All models are supplied with legs or casters installed for your convenience, for ease of cleaning underneath. The unit must be installed in a stable condition.

PLUMBING

All models are standard with a condensate evaporator pan.

The unit must be disconnected from the power source whenever performing service, maintenance functions or cleaning the refrigerated area.

Delfield · 980 S. Isabella Road, Mt. Pleasant, MI 48858 · (989) 773-7981 or (800) 733-8829 · Fax (989) 773-3210



Image 6
Contents Versa Drawer Refrigeration Units Important Warning and Safety Information Versa Drawer Refrigeration UnitsTable of Contents Specifications 115V/60Hz Receiving and Inspecting the EquipmentSerial Number Specifications 230-240V/50Hz Freestanding Models Volts Amps Plug ShipInstallation Operation Maintenance Operating ControlsDrawer Interface Control Stainless Steel Care and Cleaning General MaintenanceCleaning the Condenser Coil Never use steel pads, wire brushes or scrapersPreventive Maintenance Gasket MaintenanceDrawer Refrigeration Schematic Wiring DrawerUnits Drawer Wiring 7981 or$%4!,3 //!2$ Drawer Wiring Schematic //!2$Versa Drawer Alarm Labor of 3 Hours to Replace Labor of 1 Hour is Allowed to ReplaceLabor of 2 Hours to Replace Labor of 4 Hours to ReplaceStandard ONE Year Warranty ONE Year Parts and Labor Service Labor Contract Delfield CompanyDelfield Company Delfield Serial # Installation Model# Date General ConditionsThank you for choosing Delfield