Versa Drawer™ Refrigeration Units
INSTALLATION | ELECTRICAL CONNECTION |
Never stand on the unit or its drawers! Doing so may result in bodily injury.
LOCATION
Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents, which can be up to 1,200 pounds(550kg). Reinforce the floor as necessary to provide for maximum loading.
The location should be selected so that power cords can be connected without any extension cords.
For the most efficient operation, be sure to provide good air circulation inside and out. Avoid hot corners and locations near stoves and ovens.
Direct exposure to excessive amounts of steam in machine compartment will result in control board failure.
INSIDE CABINET
Do not pack drawer so full that air cannot circulate. Load product level with top of pans and keep all food covered.
OUTSIDE CABINET
The front louvers must be kept 24"(60cm) clear of any obstructions. Proper operation of these models is dependent on air being able to flow freely through the front louvers. Side louvers must have 24"(60cm) of clearance for service access.
Any restriction of the proper airflow outlined above, total or partial, will void the warranty on the unit.
LEVELING
The unit must be level so the drain pan will drain properly, drawers will line up with frames and the cabinet will not be subject to undue strain.
ELECTRICAL CONNECTIONS AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
UNITS EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED WITH A
A 7' (2.1 m) long grounded supply cord with three- pronged plug is provided with the standard units. Simply plug into a
Refer to the amperage data listed in the specifications, the serial number tag, your local code or the National Electrical Code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be installed for connection of the line cord or permanent connection to the unit.
Have the wall outlet checked by a qualified electrician to be sure a proper ground is present and that the outlet provides the correct voltage and required amperage to match the specifications. Do not use an adapter to connect to a
Any power cord that is frayed or damaged should be replaced. When disconnecting the unit from the power source, do not pull on the cord. Firmly grip the plug and remove from outlet.
STABILIZING
All models are supplied with legs or casters installed for your convenience, for ease of cleaning underneath. The unit must be installed in a stable condition.
PLUMBING
All models are standard with a condensate evaporator pan.
The unit must be disconnected from the power source whenever performing service, maintenance functions or cleaning the refrigerated area.
Delfield · 980 S. Isabella Road, Mt. Pleasant, MI 48858 · (989)