Versa Drawer™ Refrigeration Units

OPERATION

Internet Info

 

 

GENERAL

The Versa Drawer unit has the capability to be

Each drawer operates independently in one of four

monitored remotely using the Internet. Using NAFEM

protocol to monitor HACCP information such as cabinet

modes at any time:

and evaporator temperature as well as other key data

 

 

 

Refrigerator mode The drawer operates at a set

can be view live or past data can be pulled up.

point of 37°F (3°C), maintaining a range between 34°F

LAN line connection:

 

 

(1°C) and 40°F (4°C).

 

 

 

 

 

 

 

 

 

 

 

Freezer mode The drawer operates at a set point of

 

 

 

**Unplug unit before proceeding any further!

-3°F (-19°C), maintaining a range between -6°F

 

 

 

 

 

 

 

 

 

 

 

 

(-21°C) and 0°F (-17°C).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thaw Cabinet mode The drawer maintains

 

 

 

Note: A user provided Ethernet cable is

temperature between 36°F (2°C) and 41°F (5°C)

 

 

 

for a minimum of 4 hours or longer if required. Once

 

 

 

required

 

 

the thaw cycle is complete, the drawer mode is

1. Disconnect power.

 

 

automatically changed to refrigerator mode.

 

 

2.

Remove access panel from end of machine

Convenience Chiller mode The drawer operates as

 

compartment.

 

 

a chiller, maintaining the convenience chiller set point

 

 

 

3.

Thread Ethernet cable through hole in back of unit

of 23˚F (-5˚C) for four hours. Once the convenience

chiller cycle is complete, the drawer mode is changed

 

where power cable passes through. Connect to

to refrigerator mode.

 

Ethernet port located on back of display board.

Drawer gaskets are magnetic and mount to the drawer,

4.

If necessary secure cable to prevent interference

snapping in place and are removable without tools.

 

with condenser fan blades.

REFRIGERATION SYSTEM

5.

Connect other end of Ethernet cable to open port on

In a 4-drawer system there are two compressors;

 

store router/switch.

 

 

6.

Attach access panel to end of unit.

one operating drawers 1 and 2 and one operating

drawers 3 and 4. In a 2-drawer system there is a single

7.

Reconnect power to unit.

 

 

compressor.

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE MONITORING

8.

Contact Delfield service tech at 1-800-733-8829 with

 

the following information:

 

 

Temperature sensors are located in each drawer. The

 

 

 

Store Location

 

 

drawer temperatures are displayed on the control

 

 

 

 

 

 

 

 

 

 

 

panel.

Mac Address (To obtain the MAC address. First,

CONTROL PANEL

 

press the

 

button until “Program Menu” appears.

 

Press

button until brackets are around “SW

The control panel provides information indicating the

 

 

Version”. Write down “Gateway Mac Address ##

current mode of each individual drawer. In addition,

 

- ## - ## - ## - ## - ##” displayed on screen. Press

the actual temperature of the drawer is displayed. See

 

the

button twice to return to the main display

page 7 for control panel operation

 

screen.

 

 

 

 

 

DEFROST

After this information is received the Delfield service

An automatic defrost occurs every six hours in

 

tech will inform you on Internet site access and a

 

password to view your data.

refrigerator and freezer mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

Wireless connection:

 

 

 

 

 

Please contact Delfield for help with wireless

Chiller product Info

connections.

 

 

 

 

 

 

 

 

 

 

 

 

Note: These results are based on chilling at a cabinet

 

 

 

 

 

 

 

 

 

 

temperature of 5˚F(-15˚C) and 10 pounds(4.5kg)

 

 

 

Product

 

Chill Time

 

of product per drawer. The times are based on the

 

 

 

 

 

Mash Potatoes

 

3 hours 21 minutes

 

duration to go from 140˚F(60˚C) to 40˚F(4˚C). The

 

 

Scrambled Eggs

 

1 hour 53 minutes

 

maximum limit of product to be chilled is no more than

 

 

Green Beans

 

 

 

2 hour 49 minutes

 

10 pounds(4.5kg), not including pans. Product should

 

 

 

 

Soup (Vegatable)

 

2 hour 58

 

be covered and no more than 2"(5cm) deep in the pan.

 

 

Spaghetti with Meat sauce

 

2 hours 32 minutes

 

 

 

 

 

 

Delfield · 980 S. Isabella Road, Mt. Pleasant, MI 48858 · (989) 773-7981 or (800) 733-8829 · Fax (989) 773-3210



Image 7
Contents Versa Drawer Refrigeration Units Versa Drawer Refrigeration Units Important Warning and Safety InformationTable of Contents Receiving and Inspecting the Equipment Specifications 115V/60HzSerial Number Freestanding Models Volts Amps Plug Ship Specifications 230-240V/50HzInstallation Operation Operating Controls MaintenanceDrawer Interface Control Never use steel pads, wire brushes or scrapers General MaintenanceCleaning the Condenser Coil Stainless Steel Care and CleaningGasket Maintenance Preventive MaintenanceDrawer Refrigeration Schematic Drawer WiringUnits 7981 or Drawer Wiring$%4!,3 //!2$ //!2$ Drawer Wiring SchematicVersa Drawer Alarm Labor of 4 Hours to Replace Labor of 1 Hour is Allowed to ReplaceLabor of 2 Hours to Replace Labor of 3 Hours to ReplaceStandard ONE Year Warranty ONE Year Parts and Labor Delfield Company Service Labor ContractDelfield Company General Conditions Delfield Serial # Installation Model# DateThank you for choosing Delfield