Delfield 18600VD manual Labor of 1 Hour is Allowed to Replace, Labor of 2 Hours to Replace

Page 17

Versa Drawer™ Refrigeration Units

STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT UNDER WARRANTY

Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.

A maximum of 1-hour is allowed to diagnose a defective component.

A maximum of 1-hour is allowed for retrieval of parts not in stock.

A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.

Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work Authorization from Delfield. You must submit the number with the service claim.

LABOR OF 1 HOUR IS ALLOWED TO REPLACE:

Solenoid Coil

Hi-limit/Thermal Protector Switch

Compressor Start Components and Overload Protector

LABOR OF 2 HOURS TO REPLACE:

Drawer Tracks/Cartridges

Pressure Control

Microprocessor Control

LABOR OF 3 HOURS TO REPLACE:

• Expansion Valve

LABOR OF 4 HOURS TO REPLACE:

Compressor

This includes recovery of refrigerant and leak check.

$55.00 (USD) maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings, solder, brazing rod, nitrogen, or similar fees.)

Evaporator/Condenser Fan Motor and Blade

Door Hinges, Locks, and Gaskets

Solenoid Valve

Locate/Repair Leak

Condenser or Evaporator Coil

Refrigerants

R404A A maximum of $16.00/lb.(0.43kg) (USD).

Delfield · 980 S. Isabella Road, Mt. Pleasant, MI 48858 · (989) 773-7981 or (800) 733-8829 · Fax (989) 773-3210

16

Image 17
Contents Versa Drawer Refrigeration Units Versa Drawer Refrigeration Units Important Warning and Safety InformationTable of Contents Serial Number Specifications 115V/60HzReceiving and Inspecting the Equipment Freestanding Models Volts Amps Plug Ship Specifications 230-240V/50HzInstallation Operation Drawer Interface Control MaintenanceOperating Controls Cleaning the Condenser Coil General MaintenanceStainless Steel Care and Cleaning Never use steel pads, wire brushes or scrapersGasket Maintenance Preventive MaintenanceDrawer Refrigeration Schematic Units WiringDrawer 7981 or Drawer Wiring$%4!,3 //!2$ //!2$ Drawer Wiring SchematicVersa Drawer Alarm Labor of 2 Hours to Replace Labor of 1 Hour is Allowed to ReplaceLabor of 3 Hours to Replace Labor of 4 Hours to ReplaceStandard ONE Year Warranty ONE Year Parts and Labor Delfield Company Service Labor ContractDelfield Company General Conditions Delfield Serial # Installation Model# DateThank you for choosing Delfield