7Tank Installation Kit Includes:

6

BOLT CAP

CLOSET FLANGE

7Tank Installation Kit Includes:

2 bolts, 2 rubber washers, 4 metal washers, 4 metal nuts, 2 plastic nuts, 1 large rubber gasket.

RUBBER

WASHER

RUBBER

TANK MTG. INSTALL TOILET GASKET

BOLTS

WASHER

NUT

WASHER

NUT

CLOSET BOLT

WASHER NUT

INSTALL TOILET

a.Position toilet squarely to wall and, with a rocking motion, press bowl down fully on wax ring and flange. Alternately tighten nuts until toilet is firmly seated on floor.

!CAUTION:

DO NOT OVERTIGHTEN NUTS

b.Install caps on washers.

c.Smooth off the bead of sealant around base. Remove excess sealant.

INSTALL TANK

a.Discard plastic nuts.

b.Install tank mounting bolts and rubber washers from inside tank, through mounting holes and secure with one metal washer and one nut per bolt.

c.Install large rubber gasket over threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening.

d.With tank parallel to wall, secure tank to bowl using remaining two metal washers and nuts. Alternately tighten nuts until tank is snugged down evenly against bowl surface.

*USE NUT DRIVER OR DEEP SOCKET RACHET.

!CAUTION:

DO NOT OVERTIGHTEN NUTS MORE THAN REQUIRED FOR A SNUG FIT!

8 INSTALL TOILET SEAT Install toilet seat in accordance with manufacturer's directions.

9a

Before continuing, determine the type of water supply connection you have from

 

the chart below and use the appropriate assembly parts required to properly

 

reconnect the water supply. DO NOT use plumber's putty to seal these fittings.

METAL / COPPER

METAL FLANGED

METAL SPIRAL

VINYL / BRAIDED

FLARED TUBING

 

TUBING

TUBING

CONNECTOR

LOCK NUT

 

LOCK NUT

 

LOCK NUT

LOCK NUT

CONE

 

EXISTING

 

EXISTING

COUPLING

 

WASHER

 

WASHER

 

 

CONE

NUT

COUPLING

 

EXISTING

 

WASHER

 

 

 

 

 

NUT

 

COUPLING

 

COUPLING

 

 

 

NUT

 

NUT

 

WATER

 

WATER

 

WATER

WATER

SHUT-OFF

 

SHUT-OFF

 

SHUT-OFF

SHUT-OFF

These parts must be used as

 

Use existing

Use existing spiral

Captive cone

illustrated to insure water-tight

coupling nut

cone washer.

washers already

connection. Use of existing

 

and washer.

Fluidmaster cone

included. No

coupling nut may result in

 

 

 

washer may not

additional washers

water leakage. Water supply

 

 

 

seal completely on

needed.

tube or pipe must extend at

 

 

 

spiral type supply

 

least 1/2" inside threaded

 

 

 

line.

 

shank of valve (does not

 

 

 

 

 

 

apply to flanged tubing).

 

 

 

 

 

 

 

 

 

 

CAUTION: DO NOT USE

 

 

CAUTION: Overtightening of

CONE WASHER WITH

 

 

LOCK NUT or COUPLING NUT

 

 

could result in breakage and

PLASTIC SUPPLY LINE.

 

 

potential flooding.

9b

With correct washers in place (see Step 9a), tighten COUPLING NUT 1/4 turn beyond hand tight.

DO NOT OVERTIGHTEN.