Daewoo KOR-631H9A, KOR-631G0A, KOR-861H0A State Point, Gnd, Check no Method, Point Wave Form

Page 29

3. When there is no microwave oscillation

1) When touching START pad, oven lamp does not turn on.

Fan motor do not rotate, but cook indicator in display comes on.

*Cause : RELAY 2 does not operate. refer to Circuit Diagram (Point 3) - Check method

STATE

POINT

A

B

 

 

 

 

RELAY 2 ON

 

-5VDC

GND

RELAY 2 OFF

 

GND

-12VDC

2) When touching START pad, oven lamp turns on.

Fan motor and turntable rotate and cook indicator in display comes on.

*Cause : RELAY 1 does not operate. refer to Circuit Diagram (Point 2) - Check method

STATE

POINT

A

B

 

 

 

 

RELAY 1 ON

 

-5VDC

GND

RELAY 1 OFF

 

GND

-12VDC

4.When the door is opened during operation, the count down timer does not stop.

refer to Circuit Diagram (Point 1) -Check method

STATE

POINT

A

B

 

 

 

 

1) DOOR OPEN

 

OPEN

-5VDC

2) DOOR CLOSED

 

CLOSE

GND

CHECK NO

1

METHOD

Check the stage (ON, OFF) of the door open monitor switch by resistance measurement.

REMEDY

Replace door open monitor switch.

5.When the digital clock does not operate properly.

refer to Circuit Diagram (Point 5)

POINT

A

WAVE FORM

T:16.7ms(60Hz)

* If clock does not keep exact time, you must check resistor R15, 16 zener diode ZD1.

28

Image 29
Contents Microwave Oven Table of Contents Do not Attempt to Operate this Appliance with the Door Open Safety and PrecautionsSpecifications External View Outer DIMENSIONKOR-631G/H, 631G/H9/KOR-861G/HFeature Diagram KOR-861G0A Control PanelKOR-631H0A/631H9A/861H0A Leave space behind and side InstallationOperations and Functions Wattage output chartDisassembly and Assembly To remove cabinet Part Code Part Name Description REF no Part Code Part Name Description ’TY RemarkPage Control Panel Switch MembranePCB AS Screw Tapping T2S TRS 4X12 MfznTo remove high voltage capacitor To remove wind guide assembly Adjustment Interlock Mechanism and AdjustmentCondition Trouble Shooting GuideCheck Result CauseResult Cause Remedy CheckRelay RY1 Condition Check ResultContinuity of the membrane Touch Assembly Programming Measurement and Test Measurement of the Microwave Power OutputProcedure Microwave Radiation Test ProceduresHigh voltage transformer Component Test ProcedureWiring Diagram Printed Circuit Board Circuit Check ProcedureLoad No Load Check Point RemarkMeasure Point GND State PointCheck no Method Point Wave FormPCB Circuit Diagram C.B. Location no Name Symbol Specification Part Code QTYCEXF1C101V Capacitor Elec EC2 CEXF1C102V Connector Wafer CN1Wire Copper SJ1,SJ3 TIN Coating Total Assembly Exploded View and Parts ListDoor Assembly Part Code Part Name Description QTY Lamp LockScrew Tapping T2S PAN 4X6 Mfzn Motor SyncroScrew Tapping T2S TRS 4X30 Mfzn Special Screw T1 TRS 4*10 SE MfznFAN PP+30% Glass Screw Special TT2 TRS 4X8 SE MfznCover Wave Guide Heatpro of PP Lock POMSpecial Screw TT3 TRS 4X8 Mfzn NO. R631G0A003 Printed Date Aug