Daewoo KOR-861H0A, KOR-631G0A Trouble Shooting Guide, Condition, Check Result, Cause, Remedy

Page 19

TROUBLE SHOOTING GUIDE

Following the procedure below to check if the oven is defective or not.

1.Check grounding before trouble checking.

2.Be careful of the high voltage circuit.

3.Discharge the high voltage capacitor.

4.When checking the continuity of the switches, fuse or high voltage transformer, disconnect one lead wire from these parts and check continuity with the AC plug removed. To do otherwise may result in a false reading or damage to your meter.

NOTE : When electric parts are checked, be sure the power cord is not inserted the wall outlet.

Check wire harness, wiring and connected of the terminals and power cord before check the parts listed below.

(TROUBLE 1) Oven does not operate at all ; any inputs can not be accepted.

CONDITION

Fuse blows.

 

CHECK

 

 

 

RESULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check continuity of interlock

 

 

 

Continuity

 

 

 

 

 

 

 

monitor switch with door closed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Continuity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUSE

Malfunction of interlock moni- tor switch

REMEDY

Replace

NOTE 1

Check continuity of of primary interlock switch contact with door

partially open until interlock moni- tor switch contact close

Check continuity of primary winding of low voltage trans- former

Continuity

0or infinite

Approx.

150~310

(normal)

Shorted con- tacts of primary interlock switch.

Defective low voltage trans- former

Replace

NOTE 1

Replace

Disconnect one side of the lead wire connected form high volt- age transformer to the high volt- age capacitor and operate the unit

Normal

Fuse again

blows

Defective high voltage capacitor

Defective high voltage trans- former

Replace

Replace

18

Image 19
Contents Microwave Oven Table of Contents Do not Attempt to Operate this Appliance with the Door Open Safety and PrecautionsSpecifications External View Outer DIMENSIONKOR-631G/H, 631G/H9/KOR-861G/HFeature Diagram KOR-861G0A Control PanelKOR-631H0A/631H9A/861H0A Leave space behind and side InstallationOperations and Functions Wattage output chartDisassembly and Assembly To remove cabinet Part Code Part Name Description REF no Part Code Part Name Description ’TY RemarkPage Screw Tapping T2S TRS 4X12 Mfzn Switch MembraneControl Panel PCB ASTo remove high voltage capacitor To remove wind guide assembly Adjustment Interlock Mechanism and AdjustmentCause Trouble Shooting GuideCondition Check ResultResult Cause Remedy CheckRelay RY1 Condition Check ResultContinuity of the membrane Touch Assembly Programming Procedure Measurement of the Microwave Power OutputMeasurement and Test Microwave Radiation Test ProceduresHigh voltage transformer Component Test ProcedureWiring Diagram Check Point Remark Circuit Check ProcedurePrinted Circuit Board Load No LoadMeasure Point Point Wave Form State PointGND Check no MethodPCB Circuit Diagram C.B. Location no Name Symbol Specification Part Code QTYWire Copper SJ1,SJ3 TIN Coating CEXF1C102V Connector Wafer CN1CEXF1C101V Capacitor Elec EC2 Door Assembly Exploded View and Parts ListTotal Assembly Part Code Part Name Description QTY Motor Syncro LockLamp Screw Tapping T2S PAN 4X6 MfznScrew Special TT2 TRS 4X8 SE Mfzn Special Screw T1 TRS 4*10 SE MfznScrew Tapping T2S TRS 4X30 Mfzn FAN PP+30% GlassSpecial Screw TT3 TRS 4X8 Mfzn Lock POMCover Wave Guide Heatpro of PP NO. R631G0A003 Printed Date Aug