Daewoo KOR-631G0A, KOR-861H0A, KOR-631G9A, KOR-861G0A Microwave Radiation Test, Procedures

Page 24

2. MICROWAVE RADIATION TEST

CAUTION :

1.Make sure to check the microwave leakage before and after repair of adjustment.

2.Always start measuring of an unknown field to assure safety for operating personnel from microwave energy.

3.Do not place your hands into any suspected microwave radiation field unless the safe density level is known.

4.Care should be taken not to place the eyes in direct line with the source of microwave energy.

5.Slowly approach the unit under test until the radiometer reads an appreciable microwave leakage from the unit under the test.

PROCEDURES

1.Prepare Microwave Energy Survey Meter, 600cc glass beaker, and glass thermometer 100˚C(212˚F).

2.Pour 275cc±15cc of tap water initially at 20±5 ˚C(68±9˚F) in the 600cc glass beaker with an inside diameter of approx. 95mm(3.5in.).

3.Place it at the center of the tray and set it in a cavity.

4.Close the door and operate the oven.

5.Measure the leakage by using Microwave Energy Survey Meter with dual ranges, set to 2450MHz.

1)Measured radiation leakage must not exceed the value prescribed below. Leakage for a fully assembled oven with door normally closed must be less than 4mW/cm2.

2)When measuring the leakage, always use the 5cm(2in.) space cone with probe. Hold the probe perpendicular to the cabinet and door. Place the space cone of the probe on the door, cabinet, door seem, door viewing screen, the exhaust air vents and the suction air vents.

3)Measuring should be in a counter-clockwise direction at a rate of 1 in./sec. If the leakage of the cabinet door seem is unknown, move the probe more slowly.

4)When measuring near a corner of the door, keep the probe

perpendicular to the areas making sure the probe end at the base of the cone does not get closer than 2 in. from any metal. If it does not, erroneous reading may result.

23

Image 24
Contents Microwave Oven Table of Contents Safety and Precautions Do not Attempt to Operate this Appliance with the Door OpenSpecifications Outer DIMENSIONKOR-631G/H, 631G/H9/KOR-861G/H External ViewFeature Diagram Control Panel KOR-861G0AKOR-631H0A/631H9A/861H0A Installation Leave space behind and sideWattage output chart Operations and FunctionsDisassembly and Assembly To remove cabinet REF no Part Code Part Name Description ’TY Remark Part Code Part Name DescriptionPage Switch Membrane Control PanelPCB AS Screw Tapping T2S TRS 4X12 MfznTo remove high voltage capacitor To remove wind guide assembly Interlock Mechanism and Adjustment AdjustmentTrouble Shooting Guide ConditionCheck Result CauseCheck Result Cause RemedyCondition Check Result Relay RY1Continuity of the membrane Touch Assembly Programming Measurement of the Microwave Power Output ProcedureMeasurement and Test Procedures Microwave Radiation TestComponent Test Procedure High voltage transformerWiring Diagram Circuit Check Procedure Printed Circuit BoardLoad No Load Check Point RemarkMeasure Point State Point GNDCheck no Method Point Wave FormPCB Circuit Diagram Name Symbol Specification Part Code QTY C.B. Location noCEXF1C102V Connector Wafer CN1 Wire Copper SJ1,SJ3 TIN CoatingCEXF1C101V Capacitor Elec EC2 Exploded View and Parts List Door AssemblyTotal Assembly Part Code Part Name Description QTY Lock LampScrew Tapping T2S PAN 4X6 Mfzn Motor SyncroSpecial Screw T1 TRS 4*10 SE Mfzn Screw Tapping T2S TRS 4X30 MfznFAN PP+30% Glass Screw Special TT2 TRS 4X8 SE MfznLock POM Special Screw TT3 TRS 4X8 MfznCover Wave Guide Heatpro of PP NO. R631G0A003 Printed Date Aug