Daewoo KOR-861H0A, KOR-631G0A, KOR-631G9A Component Test Procedure, High voltage transformer

Page 25

3.COMPONENT TEST PROCEDURE

High voltage is present at the high voltage terminal of the high voltage transformer during any cooking cycle.

It is neither necessary nor advisable to attempt measurement of the high voltage.

Before touching any oven components or wiring, always unplug the oven from its power source and discharge the capacitor.

1.High voltage transformer

(1)Remove connections from the transformer terminals and check continuity.

(2)Normal readings should be as follows:

Secondary winding

Approx. 110±10%

Filament winding

Approx. 0

Primary winding

Approx. 1

2. High voltage capacitor

(1)

Check continuity of capacitor with meter on the highest OHM scale.

(2)

A normal capacitor will show continuity for a short time, and then indicate 10Monce the capacitor is charged.

(3)A shorted capacitor will show continuous continuity.

(4)An open capacitor will show constant 10M.

(5)Resistance between each terminal and chassis should be infinite.

3.High voltage diode

(1)Isolate the diode from the circuit by disconnecting the leads.

(2)With the ohmmeter set on the highest resistance scale measure the resistance across the diode terminals. Reverse the meter leads and again observe the resistance reading.

Meter with 6V, 9V or higher voltage batteries should be used to check the front-back resistance of the diode,

otherwise an infinite resistance may be read A normal diode’s resistance will be infinite in one direction and several hundred Kin the other direction.

4.Magnetron

For complete magnetron diagnosis, refer to “Measurement of the Microwave Power Output”. Continuity checks can only indicate and open filament or a shorted magnetron.

To diagnose for an open filament or a shorted magnetron.

(1)

Isolate magnetron from the circuit by disconnecting the leads.

(2)

A continuity check across magnetron filament terminals should indicate 0.1or less.

(3) A continuity check between each filament terminal and magnetron case should read open.

5.Fuse

If the fuse in the primary and monitor switch circuit is blown when the door is opened, check the primary and monitor switch before replacing the blown fuse.

In case the fuse is blown by an improper switch operation, replace the defective switch and fuse at the same time. Replace just the fuse if the switches operate normally.

24

Image 25
Contents Microwave Oven Table of Contents Do not Attempt to Operate this Appliance with the Door Open Safety and PrecautionsSpecifications External View Outer DIMENSIONKOR-631G/H, 631G/H9/KOR-861G/HFeature Diagram KOR-861G0A Control PanelKOR-631H0A/631H9A/861H0A Leave space behind and side InstallationOperations and Functions Wattage output chartDisassembly and Assembly To remove cabinet Part Code Part Name Description REF no Part Code Part Name Description ’TY RemarkPage Control Panel Switch MembranePCB AS Screw Tapping T2S TRS 4X12 MfznTo remove high voltage capacitor To remove wind guide assembly Adjustment Interlock Mechanism and AdjustmentCondition Trouble Shooting GuideCheck Result CauseResult Cause Remedy CheckRelay RY1 Condition Check ResultContinuity of the membrane Touch Assembly Programming Procedure Measurement of the Microwave Power OutputMeasurement and Test Microwave Radiation Test ProceduresHigh voltage transformer Component Test ProcedureWiring Diagram Printed Circuit Board Circuit Check ProcedureLoad No Load Check Point RemarkMeasure Point GND State PointCheck no Method Point Wave FormPCB Circuit Diagram C.B. Location no Name Symbol Specification Part Code QTYWire Copper SJ1,SJ3 TIN Coating CEXF1C102V Connector Wafer CN1CEXF1C101V Capacitor Elec EC2 Door Assembly Exploded View and Parts ListTotal Assembly Part Code Part Name Description QTY Lamp LockScrew Tapping T2S PAN 4X6 Mfzn Motor SyncroScrew Tapping T2S TRS 4X30 Mfzn Special Screw T1 TRS 4*10 SE MfznFAN PP+30% Glass Screw Special TT2 TRS 4X8 SE MfznSpecial Screw TT3 TRS 4X8 Mfzn Lock POMCover Wave Guide Heatpro of PP NO. R631G0A003 Printed Date Aug