TROUBLESHOOTING GUIDE
Following the procedure below to check if the oven is defective or not.
1.Check grounding before trouble checking.
2.Be careful of the high voltage circuit.
3.Discharge the high voltage capacitor.
4.When checking the continuity of the switches, fuse or high voltage transformer, disconnect one lead wire from these parts and check continuity with the AC plug removed. To do otherwise may result in a false reading or damage to your meter.
(TROUBLE 1) Door shut, timer set, but no cooking takes place.
Does the fan motor work when you |
| YES (Refer to next page) |
|
| ||||||
shut the door and turn the timer? |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| NO |
|
|
|
|
|
|
|
|
|
|
| YES |
|
|
|
| Continuity |
|
| |
|
|
|
|
|
|
|
| |||
Does the |
| Check continuity of interlock | Replace primary, secondary interlock | |||||||
|
|
|
| |||||||
fuse blow? |
|
| monitor switch with door shut. |
|
| switch and interlock monitor switch. | ||||
|
|
|
|
|
|
|
|
|
|
|
| NO |
|
|
| NO Continuity |
|
|
|
| |
|
|
|
|
|
|
| NO |
|
| |
|
|
|
|
|
|
|
|
| ||
|
|
|
| Replace fuse and check | Replace primary, secondary interlock | |||||
|
|
|
|
|
| |||||
|
|
|
| continuity of both interlock |
|
| switch and interlock monitor switch. | |||
|
|
|
| switch s contact and monitor |
|
|
|
| ||
|
|
|
|
|
|
|
| |||
|
|
|
| switch s contact with door |
|
|
|
| ||
|
|
|
| partially open until monitor |
|
|
|
| ||
|
|
|
| switch contact. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| Both continuity |
|
|
|
| |
|
|
|
|
|
| Normal |
| |||
|
|
|
|
|
|
| ||||
|
|
|
| Disconnect one side of the | Replace high voltage capacitor | |||||
|
|
|
| lead wire connected from |
|
| and high voltage diode. | |||
|
|
|
| transformer to the high |
|
|
|
| ||
|
|
|
|
|
|
|
| |||
|
|
|
| voltage capacitor, and operate |
|
|
|
| ||
|
|
|
| oven. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fuse again |
|
|
|
|
|
|
|
|
|
|
|
| Replace high voltage transformer | ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If outlet has proper voltage, check continuity of power supply cord.
NO Continuity
Replace power supply cord.
16