6.To remove high voltage capacitor.
1)Remove the screw which secure the grounding ring terminal of the H.V. diode and the capacitor holder.
2)Remove the H.V. diode from the capacitor holder.
3)Reverse the above steps for reassembly.
High voltage circuit wiring
7. To remove magnetron.
1) Remove the screw which secure the magnetron.
2) Remove the magnetron.
3) Reverse the above steps for reassembly.
NOTE : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to pre- vent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave leakage. It shall not exceed 4mW/cm2 for a fully assembled oven with door normally closed.
Metallic
gasket
plate
Magnetron antenna
Cooling fin
Filament terminal
<MAGNETRON>
13