TROUBLESHOOTING
First try the solutions suggested here or visit our website at www.whirlpool.com/product_help –
In Canada www.whirlpool.ca for assistance and to possibly avoid a service call.
If you experience
Possible Causes
Solution
Dryer Results (cont.)
Odors | Recent painting, staining, or | Ventilate the area. When the odors or fumes are gone from |
| varnishing in the area where your | the area, rewash and dry the clothing. |
| dryer is located. |
|
|
|
|
| For steam cycles, the water is not | Make sure water is connected to the dryer. Check that water |
| properly connected with the dryer. | inlet hose is connected to both the faucet and dryer’s water |
|
| inlet valve. Check that the water supply is turned on. |
|
|
|
| Odors are left in garments after | On some models: To remove odors left in garments after |
| wearing. | wearing, select Steam Refresh. This cycle is best for reducing |
|
| wrinkles and odors from dry loads consisting of |
|
| cotton, |
|
|
|
Load too hot | Load removed before cooldown | Allow the dryer to complete the cooldown portion of the cycle |
| portion of cycle complete. | before removing the load. |
|
|
|
| Using Timed Dry cycle with a high | Select an Automatic Cycle with a lower heat setting to avoid |
| temperature setting. | overdrying the load. |
|
|
|
Dryer Displaying Code Message or Indicator Is Lit |
| |
“PF” (power failure) | The drying cycle has been | Touch and hold START to restart the dryer. NOTE: The Control |
| interrupted by a power failure. | Lock function may be enabled when recovering from a power |
|
| failure. To unlock the control, touch and hold CONTROL LOCK |
|
| for at least 3 seconds. |
|
|
|
“L2” Diagnostic Code | There may be a problem with your | The dryer will continue to run when this diagnostic code is |
(low or no line voltage | home power supply, keeping the | present. Touch any pad to clear the code from the display |
condition) | dryer’s heater from turning on. | and return to the estimated time remaining. |
|
| NOTE: This error will only show during the initial installation. |
|
| Try the following: |
|
| Check to see if a household fuse has blown or circuit breaker |
|
| has tripped. Electric dryers use two household fuses or |
|
| breakers. Replace the fuse or reset the circuit breaker. |
|
| Confirm that the power cord is properly installed. Refer to |
|
| the Installation Instructions for details. |
|
| Select a Timed Dry heated cycle, and restart the dryer. |
|
| If the message persists, consult a qualified electrician. |
|
|
|
“F# E#” (F1 E1, F3 E1, etc.) | The dryer is in need of service. | If a code beginning with an “F” appears in the display, |
variable service codes. |
| alternating between F# and E#, the dryer control has |
|
| detected a problem that requires service. Call for service. |
Check Vent indicator is lit | The lint screen or vent is clogged; | The dryer will continue to run when this indicator is lit. |
| the vent is crushed or kinked or | Try the following: |
| has too many turns. | • Clean lint screen. |
|
| |
|
| • Check to see if the vent run from the dryer to the wall is |
|
| crushed or kinked. |
|
| • Confirm that the vent run from the dryer to the wall is free |
|
| of lint and debris. |
|
| • Confirm that the exterior vent exhaust hood is free of lint |
|
| and debris. |
|
| • Confirm that your vent system falls within the recommended |
|
| run length and number of elbows for the type of vent you |
|
| are using. Refer to “Plan Vent System” in the Installaton |
|
| Instructions for details. |
|
| • Select a Timed Dry heated cycle, and restart the dryer. |
|
| • If the indicator remains lit, have your entire home venting run |
|
| cleaned. |
|
|
|
17