Whirlpool EDP/EDN warranty General Information, 1A. Introduction, 1B. Codes and Standards

Page 3

Endurance

Page 3

 

 

 

 

SECTION 1.

General Information

1A. Introduction

EBP - This appliance is a low pressure, direct vent, hot water boiler that provides priority domestic hot water on demand as well as hydronic space heating system. The unit has a twenty gallon tank which holds boiler water (and is not domestic water storage).

The boiler water is kept hot at all times to provide immediate response to call for heat or domestic water. Domestic water is heated by the boiler water through a stainless steel plate heat exchanger.

EDP/EDN - This appliance is a low pressure, direct vent, cold start hot water boiler that provides heat for hydronic space heating.

Both appliances incorporate a circulating pump and a bypass loop, and provide circulation for the heating system and adequate flow for its own needs. It may be necessary to install a system circulator to achieve the required flow rate through the system.

Both appliances feature a forced draft, premixed combustion system. All air for combustion is supplied with the gas to the burner (flame holder). Both the

intake air and the gas are metered through separate orifices before entering the combustion air blower. The blower forces the air/fuel mixture through the flame holder and into the combustion chamber. The mixture is ignited from the hot surface ignitor and burns. Hot gases are forced out between the passes of the heat exchanger into the flue collector. Flue gases are discharged into the outside atmosphere through the vent terminal.

The appliance can operate with a concentric vent system that will provide outside air for combustion. Other venting arrangements can be provided for the appliance to include an alternative 50 equivalent feet maximum horizontal or condensate trapped vertical vent.

1B. Codes and Standards

The Endurance may be a direct vent or Category IV Boiler. All installations must be made in accordance with:

1.The National Fuel Gas Code, ANSI Z223.1 latest edition, or.

2.CAN/CGA B149 “Installation Codes for Gas Burning appliances and Equipment” and with the requirements of the local utility or other authorities having jurisdiction. Such application requirements take precedence over the general instructions contained herein.

All electrical wiring is to be done in accordance with:.

1.The National Electrical Code ANSI / NFPA70 latest edition or

Figure 1. Combo Heating/Domestic Water (Model EBP).

Figure 2. Heating Unit (Model EDP/EDN).

Image 3
Contents Endurance Table of Contents General Information 1A. Introduction1B. Codes and Standards Venting Options Endurance Laars Heating Systems For Appliances Certified as Direct Vent 2E. Air Source For Combustion when not direct vented2F. Connecting Special Gas Vent to the Appliance 2G. Securing Special Gas Vent3A. Gas Piping Length Capacity of Pipe 3B. Domestic Water Piping EBP only4A. Hydronic Piping Hydronic Heat PipingHydronic Piping EDP/EBP with Zone Valves Hydronic Piping EBP/EDP for Systems Zoned with Circulators 4C. Water Quality and Treatment Electrical ConnectionsMultiple Zones with Circulators and Room Thermostats For Your Safety Read Before Operating Fermeture DE L’ALIMENTATION EN GAZ To read or change mode Boiler Start Up6A. Common Vent Test 6C. Firing Burner 6B. Filling the SystemMaintenance and Component Description 7G. Blower 7E. Ignitor / Flame Sensor Assembly7J. Cleaning the Boiler Coil 7F. Transformer8A. Sequence of Operation Servicing8B-1. Fault Code Identification 8B. Trouble Shooting Fault CodesPower UP Fault Tree Ignition Fault Tree Space Heating Domestic HOT Water Boiler Temperature Poor flame sensor signal The boiler control EDP/EDN Wiring Diagram EBP Wiring Diagram Gas Valve Calibration Symptom Evaluations9A. Gas Valve Calibration offset adjustment 10A. Delayed ignition10B. Short Cycling 10C. Noisy Operation10D. Insufficient Hot Water EBP only 10E. High Gas Consumption Model EDP/EDN Parts IdentificationBoiler Drain Model EBPBox Lynnfield, MA Phone Fax