Solid State Logic 82S6XL090A owner manual Meter Calibration, EQ Alignments, LF EQ Maximum Gain

Page 26

XLogic E Signature™ Channel Owner’s Manual

Meter Calibration

Equipment Required:

 

Calibrated audio oscillator and audio level meter

Test Signal:

 

1kHz sinewave @ +24dBu

Input and Output:

 

Oscillator to Line Input and Output to the audio level meter

Unit Setup:

1.

Set both Line Gain and Output Gain to indent (0dB).

 

2.

Check for +24dBu output level.

Adjustment:

1.

Adjust VR24 until the ‘+24’ meter LED is just illuminated.

 

2.

Reduce oscillator level to +18dBu, then +12dBu etc. and check that the correct

 

 

meter LEDs light. At each point, reduce the level slightly using the Output Gain

 

 

control and check each LED extinguishes.

EQ Alignments

Equipment Required:

 

Calibrated audio oscillator and audio level meter

Test Signal:

 

Sinewave @ 0dBu, frequencies as specified below

Input and Output:

 

Oscillator to Line Input and Output to the audio level meter

Unit Setup:

1.

Set both Line Gain and Output Gain to indent (0dB). Check that the Filters and

 

 

Dynamics are switched out.

 

2.

Switch the EQ in and release all other EQ switches.

 

3.

Set all of the Q and Frequency controls fully anti-clockwise and all EQ gain

 

 

controls to their centre indent.

LF EQ – Maximum Gain

 

 

Adjustment:

1.

Ensure that the BLK switch is released.

 

2.

Set LF Gain to maximum and select LF BELL. Set the audio oscillator for 80Hz

 

 

and adjust LF Frequency to find the maximum level on the audio level meter.

 

3.

Adjust VR4 for +15dBu ±0.25dB.

 

4.

Switch BLK in and re-adjust LF Frequency for maximum level.

 

5.

Adjust VR6 for +18dBu ±0.25dB.

 

6.

Reset LF Gain to its centre indent position, release the BLK switch and de-select

 

 

LF BELL. Re-check the audio level meter for 0dBu.

LMF EQ – Maximum Gain

Adjustment:

1.

Ensure that the BLK switch is released.

 

2.

Set LMF Gain to maximum and LMF Q fully anti-clockwise. Set the audio

 

 

oscillator for 1kHz and adjust LMF Frequency to find the maximum level on the

 

 

audio level meter.

 

3.

Adjust VR9 for +15dBu ±0.25dB.

 

4.

Switch BLK in and re-adjust LMF Frequency for maximum level.

 

5.

Adjust VR12 for +18dBu ±0.25dB.

 

6.

Reset LMF Gain to its centre indent position and release the BLK switch. Re-

 

 

check the audio level meter for 0dBu.

HMF EQ – Maximum Gain

Adjustment:

1.

Ensure that the BLK switch is released.

 

2.

Set HMF Gain to maximum and HMF Q fully anti-clockwise. Set the audio

 

 

oscillator for 3kHz and adjust HMF Frequency to find the maximum level on the

 

 

audio level meter.

 

3.

Adjust VR14 for +15dBu ±0.25dB.

Page 22

Image 26
Contents Signature Channel Page XLogic Solid State Logic Contents XLogic E Signature Channel front XLogic E Signature Channel rearOut of Warranty Repairs WarrantyWarranty Repairs IntroductionInstallation Safety considerationsElectrical Safety Warning DefinitionsMains Isolation and Over-Current Protection Graphical SymbolsMains Supply and Phases CE CertificationInstallation Voltage SelectionMounting ConnectionChannel Block Diagram SignatureListen Mic Compressor OperationInput Section Dynamics Section Compressor/LimiterExpander/Gate Filters SectionEqualiser Section Output SectionSide Chain Processing Order Signal RoutingChannel Processing Order Stop looking we left this page blank… Appendix a Internal Links and Fuses Line Key Appendix B Connector DetailsInput Output LinkMeasurement References Appendix C Performance SpecificationMeasurement Conditions Microphone Input 1 Transformer CoupledChannel Output Microphone Input 2 Electronically BalancedLine Input Equaliser Expander/Gate Controls DynamicsCompressor/Limiter Controls Appendix D Calibration Information Output StageLF EQ Maximum Gain Meter CalibrationEQ Alignments LMF EQ Maximum GainDynamics Adjustments Appendix E Physical specification Appendix F Environmental SpecificationAppendix