Appendix
| 4. | Switch BLK in and |
| 5. | Adjust VR16 for +18dBu ±0.25dB. |
| 6. | Reset HMF Gain to its centre indent position and release the BLK switch. Re- |
|
| check the audio level meter for 0dBu. |
HF EQ – Maximum Gain |
|
|
Adjustment: | 1. | Ensure that the BLK switch is released. |
| 2. | Set HF Gain to maximum and select HF BELL. Set the audio oscillator for 12kHz |
|
| and adjust HF Frequency to find the maximum level on the audio level meter. |
| 3. | Adjust VR19 for +15dBu ±0.25dB. |
| 4. | Switch BLK in and |
| 5. | Adjust VR21 for +18dBu ±0.25dB. |
| 6. | Reset HF Gain to its centre indent position, |
|
| BLK switch. |
Dynamics Adjustments
If the dynamics circuitry requires adjustment the following procedure should be followed in the order shown, in its entirety. All presets are on the 629612 card.
Equipment Required: |
| Calibrated audio oscillator, audio level meter and a (digital) dc. volt meter |
Test Signal: |
| 1kHz sinewave unless specified otherwise, level as specified |
Input and Output: |
| Oscillator to Line Input, Output to the audio level meter. |
Unit Setup: |
| Switch the dynamics IN and the EQ and Filter sections OUT, set all of the |
|
| dynamics controls |
Unity Gain |
|
|
Adjustment: | 1. | Set the oscillator for 0dBu. |
| 2. | Adjust VR26 for 0dBu ±0.05dB. |
|
| |
Adjustment: | 1. | Set the oscillator for |
2. Measure on TP30 and adjust VR27 for
Adjustment: | 1. | Set the oscillator for 0dBu. |
| 2. | Measure on TP22 and adjust VR25 for |
Gate Threshold |
|
|
Adjustment: | 1. | Set the oscillator for +14dBu. |
| 2. | Adjust VR25 until the gate just opens. |
| 3. | Check this adjustment by changing the oscillator level a little. |
|
| necessary so that the gate just opens when a +14dBu signal @ 1kHz is applied. |
Page 23