XLogic E Signature™ Channel Owner’s Manual
Dynamics
The unit contains a | complete dynamics section, the functions of which split into two areas; |
a Compressor/Limiter and an Expander/Gate. | |
Compressor/Limiter |
|
Controls: |
|
Ratio (slope) | Variable from 1 to infinity (limit) |
Threshold | Variable from +10dB to |
Attack Slope | Normally ‘Over Easy’, switchable to ‘Hard Knee’ |
Attack Time | Normally 30mS per 20dB*, switchable to 3mS (‘Fast Att’) |
Release | Variable from 0.1 to 4 seconds |
Release Slope | Normally ‘Logarithmic’, switchable to ‘Linear’ |
The Compressor/Limiter has two different attack slope modes and two different release slope modes; ‘Hard Knee’ & ‘Over Easy’ and ‘Logarithmic’ & ‘Linear’ respectively. As their names suggest these modes affect of manner of response to incoming signals. Combining the two modes provides four very different modes of compression and limiting with the ‘Hard Knee’ and ‘Linear’ modes giving far more dramatic compression characteristics.
* When LK1 not fitted (default).
Expander/Gate |
|
Controls: |
|
Range | Variable from 0 to 40dB |
Threshold | Variable from |
Attack Time | Normally 1.5mS per 40dB, switchable to 100µs |
Release Time | Variable from 0.1 to 4 seconds |
The side chain signal can be sourced either from the signal feeding the dynamics section or the external Key input. The Filters and/or the EQ can be inserted in the sidechain.
LED meters independently indicate amount of compression and expansion.
Measurement Conditions
Signal applied to Line Input and measured at Output. All pots
THD + N (+20dBu applied) | < 0.1% at 1kHz |
Output Headroom | > +26dBu at onset of clipping |
Frequency Response | ±0.25dB from 20Hz to 20kHz |
Noise | < |