Broan 61000, 614804 manual Operation, Halogen Bulbs, Controls, Hot

Page 10

OPERATION

Controls

The hood is operated using the slide controls under the front edge of the hood.

The light switch turns the halogen lights on and off.

The blower on / off switch turns the blower on to the running speed set by the blower speed control. The blower must be turned on and off using this switch.

LIGHT

 

BLOWER

SWITCH

BLOWER

ON / OFF

 

SWITCH

 

SPEED

 

 

 

CONTROL

 

PILOT

LAMP

The blower speed control changes the speed of the blower from 1 to 3 position. The pilot lamp lights up whenever the blower is on.

HEAT SENTRY™

Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.

1)If blower is OFF - it turns blower ON to HIGH speed.

2)If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.

WARNING

The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.

HALOGEN BULBS

This range hood requires 4 halogen bulbs (Type JC, 12V, 20W, G-4 Base).

ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.

To change bulbs:

1.Loosen the ring nut by turning it counterclockwise.

2.Pull the bulb downwards to remove - DO NOT ROTATE. CAUTION: BULB MAY BE

HOT!

3.Replace with Type JC, 12V, 20W, G-4 Base halogen bulb. Do not touch replacement bulb with bare hands!

-10 -

RING NUT

Image 10
Contents Series English Français EspañolRead and Save These Instructions Intended for Domestic Cooking only ! WarningPage Prepare the Hood Install the Ductwork Install Mounting BracketsInstall the Hood Wiring 33-7/16Connect Ductwork Hood Cleaning MaintenanceGrease Filters Controls OperationHalogen Bulbs HOTWarranty Fuse ReplacementSwitchofftheelectricitysupply Seulement Pour Utilisation Domestique ! Avertissements AvertissementsPage Preparez LA Hotte Installation DU Systeme D’EVACUATION Installation DES Etriers D’ASSEMBLAGEInstallation DE LA Hotte Installation Electrique Connexion DU Systeme D’EVACUATION Filtres anti-graisse EntretienNettoyage de votre hotte Ampoules Halogenes CommandesFonctionnement AvertissementGarantie Remplacement FusibleDÉBRANCHEZL’APPAREIL LEA Y Conserve Estas Instrucciones AdvertenciaAdvertencia Prepare LA Campana Instalacion DEL Tubo DE Extraccion Instalacion DE LOS Soportes Para EL MontajeInstalacion DE LA CAMPA- NA Instalacion Electrica Entubado DE Canalizacion Filtros antigrasa MantenimientoLimpieza de la campana Lamparas Halogenas FuncionamientoMandos Garantia Sustitucion FusibleDesconectarelaparato Service Parts DescriptionListe Pieces DE Rechange Part N DescriptionLista DE Piezas DE Recambio CÓD. N Pieza N DescripciónModel 61000 48 Versions 04307144/3 K8 2m HS