Zephyr ZML-E42AG/AS manual Setting the Filter Change Reminder, Filter Replace Indicator

Page 15
Charcoal Filter Change Reminder (charcoal filter, if installed)

Charcoal Filter Change Reminder (charcoal filter, if installed)

 

 

Reminder

 

 

 

When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust

 

and fumes from cooking, then re-circulates the air within the home. These charcoal filters are required to

 

be replaced after every 120 hours of use. The charcoal filters should never be cleaned or placed in a dish

 

washer.

 

 

 

 

 

 

 

Change

The filter change reminder function in the microprocessor needs to be switched on. When switched on, the

 

microprocessor will elapse and count usage time and indicate by a flashing C

when charcoal filter

 

replacements are needed.

 

 

 

 

 

 

Setting the Filter Change Reminder

 

Set Mode

 

 

Filter

 

 

 

 

When off, hold

for approximately 5 seconds.

 

 

 

Charcoal

 

hold 5 sec.

display from

< - > to < C >

The display will change from

(exhaust mode)

to

 

C

(recirculating mode) this indicates that the

 

 

 

C

 

elapse timer function is switched on and charcoal

 

 

 

 

 

filters are used.

 

 

 

 

 

 

 

 

Filter Replace Indicator

 

 

ChangeSetModeFIlters

 

 

Controls

Re-setting Function

starts flashing, the charcoal

 

 

When the display

C

 

display < C > flashes

 

filters need to be replaced.

 

 

 

 

 

 

 

 

 

 

 

C

 

Once filters are replaced, with hood off, press and

 

To Reset

 

 

&

 

hold 5 sec.

display from

< C > to < >

hold

the display will appear;

hold for apprimately

Features

5 seconds until C

on displays disappears

.

 

C

 

 

 

 

The filter change reminder is now re-set and a new 120 hour elapse cycle is initiated.

13

Image 15
Contents Milano Island Use, Care, and Installation GuidePage Hood and Filter Cleaning Table of ContentsINSTALLATION MAINTENANCEREAD AND SAVE THESE INSTRUCTIONS Important Safety NoticeELECTRICAL REQUIREMENTS OPERATIONList of Materials MODELS ZML-M90AS, ZML-M90AG, ZML-E42AS, ZML-E42AGPARTS SUPPLIED Installation - Ducting Calculation Sheet DUCTING Installation - Mounting Height & ClearanceSoffit or crawl space OptionsInstallation - Ducting WARNING FIRE HAZARDblower housing & ceiling bracket InstallationSpecifications HoodInstallation - Mounting the Hood FIG. B FIG. CFIG. A FIG. D FIG. Ecut-down FIG. F Ductless RecirculationCharcoal Filter Replacements RECIRCULATING KIT REQUIRED IF NO DUCTING IS USEDLights On/Dim/Off Features & ControlsTouch Controls Adjust 6 Speed Levels 15 Min Delay Off 1. Blower On/OffSetting the Filter Change Reminder ReminderFilter Charcoal Filter Change Reminder charcoal filter, if installedMetal Filter Clean Indicator Filter Clean ReminderFeatures & Controls - Metal Mesh Metal Filter Clean Reminder metal mesh filterMetal Filters Maintenance - Hood and Filter CleaningSURFACE MAINTENANCE Metal Filter Dimensionsof the Maintenance - LightsCAUTION Light bulb becomes extremely hot when turned on REPLACING LIGHT BULBSCause TroubleshootingTROUBLESHOOTING PROCEDURES FOR MILANO ISLAND IssueDESCRIPTION List of Parts and AccessoriesReplacement Parts Optional AccessoriesJUN08.0101 Limited Warranty