Zephyr EGL-E30AS Installation Instructions, Venting Methods, Preparation, Pipe Ducting version

Page 8

Installation Instructions

Closely follow the instructions set out in this manual.

All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined.

VENTING METHODS

The hood is equipped with a transition B for discharge of fumes to the outside (Ducting version).

Should it not be possible to discharge cooking fumes and vapour to the outside, the hood can be used in the Ductless (recirculating) version. Attach a charcoal filter on the internal side of the metal filter and the deflector F directly on the transition (Cabinet without ceiling) or at the top of the cabinet. Fumes and vapors are recycled directly through the deflector F (Cabinet without ceiling) or by means of a duct connected to the transition B and the deflector F.

NOTE: For ductless (recirculating) version only: purchase the Ductless Recirculating Kit.

Minimum Duct Size (Ducting/Ductless version): 6" Round Pipe.

Roof pitch w/

Flashing and cap

F

Pipe

Ductless (recirculating) version*

PREPARATION

Pipe

Pipe

Ducting version

Side wall cap with gravity damper

This hood is designed to be installed inside a cabinet (only Blower unit housing) and fixed at the bottom of the cabinet, check that the cabinet, its bottom, the hanging system of the cabinet and the wall where cabinet is installed is strong enough to support the hood.

The inside of the cabinet should be accessible.

However, a qualified technician must verify suitability of the materials in accordance with the type of cabinet. We suggest to mount the cabinet onto the wall after having installed the hood.

Before making cutouts, make sure there is proper clearance.

NOTE: For ductless (recirculating) version only: Check that there is enough clearance from ceiling and deflector once this last has been mounted to let an easy recirculation of air.

Hood installation height above cooktop is the users preference. The lower the hood above the cooktop, the more efficient the capturing of cooking odors, grease and smoke.

The hood shall be installed at 24" minimum to 32" above the countertop.

Check your ceiling height and the hood height maximum before you select your hood.

8

Image 8
Contents Use, Care, and Installation Guide Page Table of Contents Important safety Notice OperationElectrical Requirements Electrical & Installation requirementsBefore Installing the Hood Parts not Supplied List of MaterialsParts Supplied Dimensions and clearances Ductless recirculating version 3/8Installation Instructions Closely follow the instructions set out in this manualVenting Methods PreparationInstallation Ductwork Calculation Sheet Installation Cabinet with ceilingInstallation Adjusting Electrical connection Failure to do so can result in death or electrical shockDescription of the hood Reset filter saturation signal ControlsDescription of control panel Controlling the range hood with sliding glassMaintenance CleaningGrease Filter Replacing the Light BulbTrouble Shooting Issue Cause What to doWarranty To Obtain Service Under WarrantyZRC-00GL List of Part and AccessoriesGF02ZA