Zephyr EGL-E36AS, EGL-E30AS manual Installation Ductwork Calculation Sheet

Page 9

www.zephyronline.com

Duct pieces

Equivalent number

 

 

lenght x used

=

Total

3 1/4 ” x 10”

1 Ft.

x (

) =

Ft.

Rect.,

 

 

 

 

straight

 

 

 

 

6 ” Round,,

1 Ft.

x (

) =

Ft.

straight

 

 

 

 

7", 8”

1 Ft.

x (

) =

Ft.

Round,,

 

 

 

 

straight

 

 

 

 

3 1/4 ” x 10”

15 Ft.

x (

) =

Ft.

Rect.90°

 

 

 

 

elbow

 

 

 

 

3 1/4 ” x 10”

9 Ft.

x (

) =

Ft.

Rect.45°

 

 

 

 

elbow

 

 

 

 

3 1/4 ” x 10”

24 Ft.

x (

) =

Ft.

Rect.90°

 

 

 

 

flat elbow

 

 

 

 

3 1/4 ” x 10”

30 Ft.

x (

) =

Ft.

Rect.

 

 

 

 

wall cap

 

 

 

 

with damper

 

 

 

 

3 1/4 ” x 10”

5 Ft.

x (

) =

Ft.

Rect.to

 

 

 

 

6 ” round

 

 

 

 

transition

 

 

 

 

3 1/4 ” x 10”

15 Ft.

x (

) =

Ft.

Rect.to

 

 

 

 

6 ” round

 

 

 

 

transition

 

 

 

 

90° elbow

 

 

 

 

6 ” Round,,

15 Ft.

x (

) =

Ft.

90° elbow

 

 

 

 

6 ” Round,,

9 Ft.

x (

) =

Ft.

45°elbow

 

 

 

 

 

Subtotal column 1 =

 

Maximum Duct Length: For satisfactory air movement, the total

duct length should not exceed 100 equivalent feet.

Duct pieces

Equivalent number

 

 

lenght x used

=

Total

6" Round

30 Ft.

x (

) =

Ft.

wall cap

 

 

 

 

with damper

 

 

 

 

6” Round,

30 Ft.

x (

) =

Ft.

roof cap

 

 

 

 

6” Round to

1 Ft.

x (

) =

Ft.

3 1/4 ” x 10”

 

 

 

 

rect.

 

 

 

 

transition

 

 

 

 

6” Round to

16 Ft.

x (

) =

Ft.

3 1/4 ” x 10”

 

 

 

 

rect.

 

 

 

 

transition

 

 

 

 

90° elbow

 

 

 

 

7", 8" round

15 Ft.

x (

) =

Ft.

90° elbow

 

 

 

 

7", 8" round

9 Ft.

x (

) =

Ft.

45° elbow

 

 

 

 

7", 8" Round

30 Ft.

x (

) =

Ft.

wall cap

 

 

 

 

with damper

 

 

 

 

7", 8"

30 Ft.

x (

) =

Ft.

Round,

 

 

 

 

roof cap

 

 

 

 

7” Round to

8 Ft.

x (

) =

Ft.

3 1/4 ” x 10”

 

 

 

 

rect.

 

 

 

 

transition

 

 

 

 

7” Round to

15 Ft.

x (

) =

Ft.

3 1/4 ” x 10”

 

 

 

 

rect.

 

 

 

 

transition

 

 

 

 

90° elbow

 

 

 

 

 

Subtotal column 2 =

 

Subtotal column 2 =

 

Total ductwork

 

=

Installation - Ductwork Calculation Sheet

9

Image 9
Contents Use, Care, and Installation Guide Page Table of Contents Operation Important safety NoticeElectrical & Installation requirements Before Installing the HoodElectrical Requirements List of Materials Parts SuppliedParts not Supplied Ductless recirculating version 3/8 Dimensions and clearancesClosely follow the instructions set out in this manual Installation InstructionsVenting Methods PreparationInstallation Ductwork Calculation Sheet Cabinet with ceiling InstallationInstallation Adjusting Failure to do so can result in death or electrical shock Electrical connectionDescription of the hood Controls Reset filter saturation signalDescription of control panel Controlling the range hood with sliding glassCleaning MaintenanceGrease Filter Replacing the Light BulbIssue Cause What to do Trouble ShootingTo Obtain Service Under Warranty WarrantyList of Part and Accessories GF02ZAZRC-00GL