Zephyr AK7836ASX, AK7842ASX, AK7848ASX manual Operation

Page 5

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

CAUTION

To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages.

OPERATION

Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.

The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.

*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.

ELECTRICAL REQUIREMENTS

Important:

Observe all governing codes and ordinances.

It is the customer’s responsibility:

-To contact a qualified electrical installer.

-To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure the range hood is properly grounded. Do not have a fuse in the neutral or ground circuit.

*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575

This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product.

A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase and install appropriate connector if necessary.

AK7836ASX, 70 Watts, 0.58 Amps

AK7842ASX, 70 Watts, 0.58 Amps

AK7848ASX, 105 Watts, 0.87 Amps

AC power listed above is for hood with lights only. See blower specs on our website for more AC power details.

INTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA.

SUITABLE FOR USE IN DAMP LOCATIONS WHEN INSTALLED IN A GFCI PROTECTED BRANCH-CIRCUIT.

Important Safety Notice

3

Image 5
Contents Use, Care, and Installation Guide Page Installation Table of ContentsTo Reduce the Risk of Range TOP Grease Fire Important Safety NoticeOperation Parts Supplied List of MaterialsDuct pieces Equivalent number Total Length x used Installation Ducting Calculation SheetDucting InstallationMounting Height & Clearance Some Ducting Options OptionsMarine Grade 316S Body Installation SpecificationsCable Lock Installation ElectricalElectrical 12 3/8 Installation Mounting the Range HoodCBI-600B and PBI-1100A Blower Installation Installation Single and Dual Internal BlowersBlower Preparation CBE-1000 External or PBN-1000A IN-LINE Blower InstallationBlower Speed Selection Features & Controls Rocker Switch ControlsSurface Maintenance Cleaning and Filter RemovalMaintenance Replacing Light Bulbs Maintenance LightsIssue Cause What to do TroubleshootingTroubleshooting Procedures for Cypress Replacement Parts List of Parts and AccessoriesOptional Accessories Description