Zephyr AK7848ASX, AK7842ASX, AK7836ASX manual Installation Ducting Calculation Sheet

Page 7

Duct pieces

Equivalent number

 

Total

 

length x used

=

 

3-1/ 4” x 10”

1 Ft.

x (

)

=

Ft.

Rect.,

 

 

 

 

 

straight

 

 

 

 

 

6” Round,

1 Ft.

x (

)

=

Ft.

straight

 

 

 

 

 

7”-10” Round,

1 Ft.

x (

)

=

Ft.

straight

 

 

 

 

 

3-1/ 4” x 10”

15 Ft.

x (

)

=

Ft.

Rect.900

 

 

 

 

 

elbow

 

 

 

 

 

3-1/ 4” x 10”

9 Ft.

x (

)

=

Ft.

Rect.450

 

 

 

 

 

elbow

 

 

 

 

 

3-1/ 4” x 10”

24 Ft.

x (

)

=

Ft.

Rect.900

 

 

 

 

 

flat elbow

 

 

 

 

 

3-1/ 4” x 10”

30 Ft.

x (

)

=

Ft.

Rect.

 

 

 

 

 

wall cap

 

 

 

 

 

with damper

 

 

 

 

 

3-1/ 4” x 10”

5 Ft.

x (

)

=

Ft.

Rect.to

 

 

 

 

 

6” round

 

 

 

 

 

transition

 

 

 

 

 

3-1/ 4” x 10”

20 Ft.

x (

)

=

Ft.

Rect.to

 

 

 

 

 

6” round

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

6” Round,

15 Ft.

x (

)

=

Ft.

900 elbow

 

 

 

 

 

6” Round,

9 Ft.

x (

)

=

Ft.

450 elbow

 

 

 

 

 

 

Subtotal column 1 =

Ft.

Duct pieces

Equivalent number

 

Total

 

length x used

=

 

6” Round

30 Ft.

x (

)

=

Ft.

wall cap

 

 

 

 

 

with damper

 

 

 

 

 

6” Round,

30 Ft.

x (

)

=

Ft.

roof cap

 

 

 

 

 

6” round to

1 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

6” round to

16 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

7” - 10”

15 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

900 elbow

 

 

 

 

 

7” - 10”

9 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

450 elbow

 

 

 

 

 

7” - 10”

30 Ft.

x (

)

=

Ft.

Round

 

 

 

 

 

wall cap

 

 

 

 

 

with damper

 

 

 

 

 

7” - 10”

30 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

roof cap

 

 

 

 

 

7” round to

8 Ft.

x (

)

=

Ft.

31/ 4” x 10” rect. transition

7” round to

23 Ft.

x (

) =

 

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

 

 

 

 

 

900 elbow

 

 

 

 

 

 

 

 

Subtotal column 2 =

 

Ft.

Subtotal column 1 =

 

 

 

Ft.

Total ductwork

=

 

 

 

Ft.

Installation – Ducting Calculation Sheet

Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet.

5

Image 7
Contents Use, Care, and Installation Guide Page Installation Table of ContentsTo Reduce the Risk of Range TOP Grease Fire Important Safety NoticeOperation Parts Supplied List of MaterialsDuct pieces Equivalent number Total Length x used Installation Ducting Calculation SheetMounting Height & Clearance InstallationDucting Some Ducting Options OptionsMarine Grade 316S Body Installation SpecificationsElectrical Installation ElectricalCable Lock 12 3/8 Installation Mounting the Range HoodCBI-600B and PBI-1100A Blower Installation Installation Single and Dual Internal BlowersBlower Preparation CBE-1000 External or PBN-1000A IN-LINE Blower InstallationBlower Speed Selection Features & Controls Rocker Switch ControlsMaintenance Cleaning and Filter RemovalSurface Maintenance Replacing Light Bulbs Maintenance LightsTroubleshooting Procedures for Cypress TroubleshootingIssue Cause What to do Description List of Parts and AccessoriesReplacement Parts Optional Accessories