Zephyr AK7836ASX, AK7842ASX, AK7848ASX manual Mounting Height & Clearance, Installation, Ducting

Page 8

www.zephyronline.com

Mounting Height & Clearance

12”*

18"

Min 30" - Max 36"

36"

*shown with 12" duct cover

Minimum mount height between range top to hood bottom should be no less than 30”.

Maximum mount height should be no higher than 36”.

It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its performance and efficiency.

If available, also refer range manufacturer’s height clearance requirements and recommended hood mounting height above range.

Vertical Ducting:

6” round minimum (singe blower)

10” round minimum (dual, in-line, and external blowers)

No horizontal option available

Installation

DUCTING

A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air flow efficiency for single blower and 10” round duct for dual, in-line, and external blowers.

Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.

Also use calculation (on page 5) to compute total available duct run when using elbows, transitions and caps.

ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size.

If turns or transitions are required; install as far away from hood duct output and as far apart, between the two as possible.

6

Image 8
Contents Use, Care, and Installation Guide Page Table of Contents InstallationImportant Safety Notice To Reduce the Risk of Range TOP Grease FireOperation List of Materials Parts SuppliedInstallation Ducting Calculation Sheet Duct pieces Equivalent number Total Length x usedDucting InstallationMounting Height & Clearance Options Some Ducting OptionsInstallation Specifications Marine Grade 316S BodyCable Lock Installation ElectricalElectrical Installation Mounting the Range Hood 12 3/8Installation Single and Dual Internal Blowers CBI-600B and PBI-1100A Blower InstallationCBE-1000 External or PBN-1000A IN-LINE Blower Installation Blower PreparationFeatures & Controls Rocker Switch Controls Blower Speed SelectionSurface Maintenance Cleaning and Filter RemovalMaintenance Maintenance Lights Replacing Light BulbsIssue Cause What to do TroubleshootingTroubleshooting Procedures for Cypress List of Parts and Accessories Replacement PartsOptional Accessories Description