Wolf Appliance Company PW482718R, PW482210R, PWC482418R L F PRO Ventilation Hood U S E & C a R E

Page 15

W O L F PRO VENTILATION HOOD U S E & C A R E

H A L O G E N L I G H T I N G

H E AT L A M P S

All Wolf Pro ventilation hoods and hood liners have halogen lighting with two settings. Halogen bulbs are included with the hood.

Pro wall hoods, 30" (762), 36" (914) and 42" (1067) wide require two 50W, 120V par 20 halogen bulbs. 48" (1219), 54" (1372), 60" (1524) and 66" (1676) wide hoods require three 50W, 120V par 20 halogen bulbs.

Pro wall chimney hoods, 36" (914) and 42" (1067) wide require two 50W, 120V par 20 halogen bulbs. 48" (1219) and 54" (1372) wide hoods require three 50W, 120V par 20 halogen bulbs.

Pro island hoods, 36" (914) and 42" (1067) wide require two 50W, 120V par 20 halogen bulbs. 54" (1372) and 66" (1676) wide hoods require three 50W, 120V par 20 halogen bulbs.

Pro hood liners, 34" (864), 40" (1016) and 46" (1168) wide require two 50W, 120V MR-16 halogen bulbs. 52" (1321) and 58" (1473) wide hood liners require three 50W, 120V MR-16 halogen bulbs.

To replace halogen bulbs, turn off the ventila- tion hood blower and lights. Once the halogen bulb is cool, use a soft cloth to unscrew the bulb and replace.

Be sure that the bulb is cool before replacing. Halogen bulbs get hot instantly and adjacent parts may retain heat.

Wolf Pro 27" (686) deep wall hoods are equipped with two heat lamp locations that require R40, 250W maximum bulbs. Heat lamp bulbs are not included with the hood.

To replace, turn off the ventilation hood blower and lights. Once the heat lamp bulb is cool, use a soft cloth to unscrew the bulb and replace.

Be sure that the heat lamp bulb is cool before touching.

Dimensions in parentheses are in

 

millimeters unless otherwise specified.

15

Image 15
Contents USE & Care Information N T E N T S Wolf Customer Service Website Wolfappliance.com T R O D U C I N G Wolf PRO Ventilation Hoods Thank YOUN TA C T F O R M AT I O N F E T Y I N S T R U C T I O N S a N D P R E C a U T I O N S Please read specification label on Clean ventilating fans frequently USE AN Extinguisher only if Model PW482210R shown L F PRO Ventilation Hood F E AT U R E SPRO LOW- Profile Wall H O O D S W- P R O F I L E WA L L H O O DModel PW482418R shown L F R R a N T YModel PW482718R shown PRO 27 686 Deep Wall H O O D SModel PWC482418R shown PRO Wall Chimney H O O D SWA L L C H I M N E Y H O O D L F WA R R a N T YPRO Island H O O D S L a N D H O O DModel PI543418R shown Model PL462212 shown O H O O D L I N E RRecessed controls Filter reinstallation-27 686 deep wall hood shownHeat Sentry F E AT U R E Filter R E M O VA LL F PRO Ventilation Hood U S E & C a R E L O G E N L I G H T I N G AT L a M P SBe sure that the heat lamp bulb is cool before touching G N AT U R E P O L I S H Cleaning a N D CareDo not operate Cleaning a N D Care Troubleshooting G U I D EF O R E C a L L I N G F O R S E RV I C E L F S E RV I C E I N F O R M AT I O NFull TWO Year Warranty 0 2 6 0 0