Kramer Electronics FC-50 user manual Overview, About the Power Connect Feature

Page 5

Overview

3Overview

The high-quality Kramer MultiTOOLS FC-50RS-232 Range Extender can connect either to a PC or to a device (for example, a switcher). By connecting two units (purchased separately) via a CAT 5 cable, the PC can control the switcher over a range of up to 1000 meters (3300 feet).

In particular, the FC-50features:

Bidirectional RS-232 operation

The Power Connect feature

A CONNECTION switch to select between a crossed and a straight connection

A PC/DEVICE pushbutton that is pressed or released if a device or a PC, respectively, are connected to the RS-232 port

12V DC power

3.1About the Power Connect Feature

The Power Connect feature applies as long as the cable can carry power. This feature is available when using STP cable and the distance does not exceed 50m (164ft) on standard CAT 5 cable. For longer distances, heavier gauge cable should be used (TP cable is still suitable for the video/audio transmission, but not for feeding the power at these distances). For units which are connected via RJ-45 connectors, make sure that the shield of the STP cable is connected to the metal casing of the connectors on both ends of the cable. For units which are connected via terminal block connectors, the shield of the STP cable must be connected to a ground terminal on the units at both ends (use the ground terminal of the power supply connection if necessary).

For a TP cable exceeding a distance of 50m, separate power supplies should be connected to the transmitter and to the receiver simultaneously.

3.2Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP)

We recommend that you use Shielded Twisted Pair (STP) cable, and stress that the compliance to electromagnetic interference was tested using STP cable. There are different levels of STP cable available, and we advise you to use the best quality STP cable that you can afford. Our non-skew-free cable, Kramer BC-STPis intended for analog signals where skewing is not an issue.

In cases where there is skewing, our Unshielded Twisted Pair (UTP) skew- free cable, Kramer BC-XTP, may be advantageous, and UTP cable might

3

Image 5
Contents Model Tables ContentsGetting Started IntroductionQuick Start Shielded Twisted Pair STP / Unshielded Twisted Pair UTP About the Power Connect FeatureOverview Recommendations for Achieving the Best Performance Your FC-50 RS-232 Range ExtenderFC-50 RS-232 Range Extender Underside Features FC-50 RS-232 Range Extender FeaturesConnecting the FC-50 RS-232 Range Extender Connecting the FC-50 RS-232 Range ExtenderCAT 5 Pinout Wiring the CAT 5 Line in / Line OUT RJ-45 ConnectorsTechnical Specifications1 of the FC-50 Technical SpecificationsPage 2900-000333 REV