3

MTD-ERV 350 Methods of Operation

The MTD-ERV 350 has been designed and produced as a system for controlled ventilation of residential buildings. It comprises two air ßows that hygienically exchange their energy.

EG

A

I

C

H

FilterJ

B

F

D

áPolluted air is drawn off by the exhaust air fan (A) from, for example, the kitchen, toilet and shower (B).

áThe heat exchanger (C) absorbs the heat from the exhaust air.

áThe supply air fan (D) draws in fresh air from outside (E).

áThe heat exchanger (C) heats up the intaken air using the heat absorbed from the exhaust air.

áIf a moisture exchanger is installed (option), moisture is also transferred from the exhaust air to the sup- ply air (for further information, see section 2.1.6).

áThe heated fresh air is delivered into the living rooms and bedrooms (F).

áThe now cooled polluted air from the kitchen, bathroom and toilet is discharged into the atmosphere (G).

áThe bypass (H) allows the exhaust air to be discharged to the atmosphere without passing through the heat exchanger so that no heat is transferred to the fresh air (for further information, see section 2.1.3).

áThe preheater (I) (option) ensures preheating of outside air so that balanced ventilation with heat recov- ery is assured even with moderate to severe frost (up to 150 m³/h at -15¡ C) (for further information, see section 3.4.2).

áThe post-heater (J) (option) additionally heats the supply air (after it has already been heated in the heat exchanger) before it is delivered into the living rooms (for further information, see section 3.4.3).

The balanced ventilation system contributes to energy saving, a healthy room climate and an optimum living climate and prevents problems with moisture.

3.4. Additional Options

Only for MTD-ERV 350 Luxury versions, with the exception of the preheater that can be installed in any MTD- ERV 350.

Please refer to the identification plate on the top of the MTD-ERV 350 to determine whether you have a basic or luxury version of the system.

These are external devices that can be connected to the MTD-ERV 350 Luxury versions (preheater also to Basic versions).

3.4.1. Preheater in MTD-ERV 350

All MTD-ERV 350 systems with “VV” in the device name (see identification plate on the top of the MTD-ERV

350)are equipped as standard with a preheater. All other MTD-ERV 350 versions can be equipped with a pre- heater as an option.

The preheater is a heating element that is in- stalled in the outside air duct of the MTD-ERV 350 just upline of the heat exchanger. The preheater heats the cold outside air before it reaches the heat exchanger in the event of moderate to se- vere frost. In this way the heat exchanger is pro- tected against freezing in addition to the standard frost protection system.

The advantage of the preheater compared with the standard frost protection system is that balanced ventilation can be maintained even in the event of frost. In the event of a frost risk, the intake of out-

Function of the System 19

Image 23
Contents MTD-ERV 350 All rights reserved Table of Contents Checking the Scope of Supply Foreword CE SymbolWarranty and Liability Warranty will be voided ifSymbols Used SafetySafety Precautions SafetyInstallationsandSafetyMeasuresDefinition of Terms CC Ease Operating Unit Moisture Recovery OptionAvailable Operating Aids 2 3-position Switch Option ReadingandSettingComfortTemperature Setting Date and TimeReading off the comfort temperature Bathroom Switch OptionReading off the ventilation level Setting the comfort temperatureReadingandSettingVentilationLevel Setting the ventilation levelSwitchingSupplyandExhaustAirFansOn and Off Switching Extractor Hood On and Off OptionWeekday fan position Weekend fan position Setting Ventilation ProgrammeReturn to the main window Access to the P menusMaking settings in the P menus Setting Additional Functions via the P MenusMenu P1 ! Status of the functions Menu P2 ! Set time delaysMenu P9 ! Status of the functions from menu P5 Setting Ventilation Using Bathroom Switches Use of the Switches OptionService by the User Setting Ventilation Using 3-position SwitchesCleaning or Replacing Filters For cleaningFor replacement Malfunctions Cleaning Valves in the Home2 3-positionSwitchwithMalfunctionLED On the position of the valvesWhat to Do in the Event of a Malfunction? End of Service LifeControlled Ventilation System Components of the Balanced Ventilation SystemMTD-ERV Preheater in MTD-ERV MTD-ERV 350 Methods of OperationAdditional Options Post-heater* in Duct System Ventilation via Extractor HoodRH Sensor* in the Home 4 CO2 Sensor* in the HomeUnderground Geothermal Heat Exchanger Technical Specifications Power supply Dimension Sketch Checking the Scope of Supply Preconditions for InstallationInstallation of the MTD-ERV Transport and UnpackingConnection of the Condensation Drain Wall MountingConnection of the Air Ducts MTD-ERV 350 Right Commissioning the MTD-ERVSelect a value for the parameter with or Menu P3 ! Set ventilation controls Menu P4 ! Read off the temperatures % and ppmMenu P5 ! Setting additional control functions Menu P7 ! Read off malfunctions and system information Menu P6  Setting additional control functionsExplanation Menu P8  Open-loop and closed-loop controlInspection of Heat Exchanger and Fans Setting the Air SpecificationsMaintenance by the Installer MTD-ERV 350 R MTD-ERV 350 LFilter Cleaning, if Preheater is Fitted Code Description Malfunction Indications on the CC Ease DisplayAvoid contact with the PCB Malfunction indications on the CC Ease Display à RemedyReset unit MIN MED T1 OK? A0 / A10 / A11 Problem/Malfunction Cause Check / measure Malfunctions or Problems without IndicationsNumber Part Spare PartsSupply air Wiring Diagram MTD-ERV 350 LEFT-HAND Standard VersionSupply air Wiring Diagram MTD-ERV 350 LEFT-HAND Luxury VersionWiring Diagram MTD-ERV 350 RIGHT-HAND Standard Version Wiring Diagram MTD-ERV 350 RIGHT-HAND Luxury Version EC Declaration of Conformity EC Declaration of ConformityPage

ERV 350, ERV 365 specifications

The MTD ERV 365 and ERV 350 are advanced energy recovery ventilation (ERV) systems designed to enhance indoor air quality and energy efficiency in residential and commercial buildings. These units utilize cutting-edge technologies to transfer heat and moisture between incoming and outgoing air streams, optimizing the temperature and humidity levels of the conditioned air.

One of the main features of the MTD ERV 365 is its high energy recovery efficiency. Equipped with a specially designed heat exchanger, this ERV can reclaim a significant portion of the energy from the exhaust air, reducing the heating and cooling load on HVAC systems. This results in lower energy bills and decreased environmental impact. The ERV 350 offers similar benefits but is tailored for slightly smaller spaces, making it suitable for various residential applications.

Both models are constructed with durability in mind, featuring robust housing and weather-resistant materials that ensure long-lasting performance. The MTD ERV series is designed to withstand varying environmental conditions, ensuring reliable operation in challenging climates. Additionally, noise-reduction technology minimizes operational sounds, promoting a peaceful indoor environment.

User-friendly controls are another highlight of the MTD ERV systems. They come equipped with intuitive interfaces, allowing users to easily adjust settings, monitor performance, and receive maintenance notifications. Advanced sensors provide real-time data on indoor air quality parameters, ensuring optimal operation based on the specific needs of the environment.

Installation and maintenance are made straightforward with these ERV units. They feature a compact design that facilitates integration into existing HVAC systems or new constructions. Filters are easily accessible for routine cleaning or replacement, maintaining peak performance over time.

Furthermore, both the MTD ERV 365 and ERV 350 are designed with sustainability in mind. Using materials that are recyclable and energy-efficient components contributes to a reduced carbon footprint. These ERV systems also comply with various building codes and standards, ensuring they meet industry requirements for safety and efficiency.

In summary, the MTD ERV 365 and ERV 350 are sophisticated energy recovery ventilation solutions that combine advanced technologies and user-friendly features. With high energy recovery efficiency, durable construction, and easy integration, they stand out as models for improving indoor air quality and energy efficiency in a variety of settings.