Pitco Frialator VF35 operation manual To the PURCHASER, Owner and Store Manager

Page 2

TO THE PURCHASER, OWNER AND STORE MANAGER

Please review these warnings prior to posting them in a prominent location for reference

TO THE PURCHASER

Post in a prominent location the instructions to be followed in the event that an operator smells gas. Obtain this information from your local gas supplier.

FOR YOUR PROTECTION

DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Do not spray aerosols in the vicinity of this appliance when it is in operation.

WARNING

Improper installation, operation, alteration, adjustments, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operation, servicing this appliance.

WARNING

Installation, maintenance and repairs should be performed by a Pitco Authorized Service and Parts (ASAP) company technician or other qualified personnel. Installation, maintenance or repairs by an unauthorized and unqualified personnel will void the warranty.

WARNING

Installation and all connections must be made according to local codes in force. In the absence of local codes in North America, the installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas and Propane Installation Code CSA B149.1 as applicable. In Australia, the appliance must be installed in compliance with AS/NZS 5601.

WARNING

During the warranty period if a customer elects to use a non-original part or modifies an original part purchased from Pitco and/or its Authorized Service and Parts (ASAP) companies, this warranty will be void. In addition, Pitco and its affiliates will not be liable for any claims, damages or expenses incurred by the customer which arises directly or indirectly, in whole or in part, due to the installation of any modified part and/or received from an unauthorized service center.

WARNING

Adequate means must be provided to LIMIT the movement or this appliance without depending on the gas or electrical cord connection. Single appliances equipped with legs must be stabilized by installing anchor straps. All appliances equipped with casters must be stabilized by installing restraining chains.

WARNING

DO NOT alter or remove structural material on the appliance to accommodate placement under a ventilation hood.

WARNING

If the appliance is equipped with a power cord and it is damaged, it must be replaced by a Pitco Authorized Service and Parts (ASAP) company technician or a similarly qualified person in order to avoid a hazard.

WARNING

The power supply must be disconnected before servicing, maintaining or cleaning this appliance.

WARNING

The appliance is NOT jet stream approved. DO NOT clean the appliance with a water jet.

WARNING

DO NOT attempt to move this appliance or transfer hot liquids from one container to another when the unit is at operating temperature or filled with hot liquids. Serious personal injury could result if skin comes in contact with the hot surfaces or liquids.

WARNING

DO NOT use an open flame to check for gas leaks!

WARNING

DO NOT sit or stand on this appliance. The appliance’s front panel, tank, splash back, tank cover, work shelf, drain board is not a step. Serious injury could result from slipping, falling or contact with hot liquids.

WARNING

NEVER use the appliance as a step for cleaning or accessing the ventilation hood. Serious injury could result from slips, trips or from contacting hot liquids.

WARNING

The oil/shortening level should NOT fall below the minimum indicated level line at any time. The use of old shortening can be dangerous as it will have a reduced flash point and be more prone to surge boiling.

WARNING

Completely shut the appliance down when shortening/oil is being drained from the appliance. This will prevent the appliance from heating up during the draining and filling process. Serious injury can occur.

WARNING

This appliance is intended for indoor use only.

WARNING

DO NOT operate appliance unless all panels and access covers are attached correctly.

WARNING

It is recommended that this appliance be inspected by a qualified service technician for proper performance and operation on a yearly basis.

WARNING

There is an open flame inside this appliance. The unit may get hot enough to set nearby materials on fire. Keep the area around the appliance free from combustibles.

WARNING

DO NOT supply the appliance with a gas that is not indicated on the data plate. If you need to convert the appliance to another type of fuel, contact your dealer.

WARNING

If gas flow to appliance is interrupted, or pilots extinguish, wait 5 minutes before attempting to relight the pilot to allow any residual gas in appliance to dissipate.

WARNING

Ensure that the appliance can get enough air to keep the flame burning correctly. If the flame is starved for air, it can give off a dangerous carbon monoxide gas. Carbon monoxide is a clear odorless gas that can cause suffocation.

WARNING

Never add oil to the appliance when it is at operating temperature. Splashing hot oil can cause severe injuries.

WARNING

Never add water to hot oil. Violent boiling can occur causing severe injury.

WARNING

This appliance is intended for professional use only and should be operated by fully trained and qualified personnel.

WARNING

To avoid splashing of hot liquid when installed, this fryer must be restrained either by the manner of installation, or with adequate ties to prevent tipping.

WARNING

An appliance equipped with casters and a flexible gas line must be connected to the gas supply with a quick disconnect device. In North America, gas appliances equipped with casters must be installed with connectors that comply with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69.CSA 6.16 Latest Edition. This connection should include a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use With Gas Fuel ANSI Z221.41.CSA 6.9 Latest Edition. In Australia, an appliance equipped with casters and a flexible gas line must be connected to the gas supply with a quick disconnect device that complies with AS 4627. The hose must comply with AS/NZS 1869 and be class B or D and have a restraining cable. The restraining cable must not exceed 80% of the length of the flexible gas line.

2

L20-418 Rev 0 9/13

Image 2
Contents No OPTION/STAND Alone To the PURCHASER, Owner and Store Manager Standard Accessories Table of Contents Installation Clearances Checking And Unpacking Your New ApplianceLeveling The Fryer Legs/Casters Caster and leg typesFuel Types Fuel Supply Line Leak and Pressure TestingGas Connection Quick Disconnect Gas ConnectionVentilation And Fire Safety Systems Gas Line RequirementsLighting Instructions Initial CleaningDaily Cleaning Weekly Fryer Cleaning Thermostat Calibration CheckFilling The Fryer With Solid Shortening Thermostat CalibrationFilling The Fryer With Liquid Shortening Fryer Shut-DownL20-418 Rev 0 9/13
Related manuals
Manual 16 pages 11.4 Kb

VF35 specifications

The Pitco Frialator VF35 stands as an exemplary model in the world of commercial frying equipment, known for its efficiency, reliability, and technology-driven features that cater to the demands of modern kitchens. Designed for high-volume frying, the VF35 is the go-to choice for restaurants, cafeterias, and catering operations looking for quality and performance.

One of the most notable features of the VF35 is its fry tank capacity, accommodating up to 35 pounds of oil, allowing for large batches of food to be cooked simultaneously. The unit is designed with a robust stainless-steel construction, ensuring durability and resistance to corrosion while maintaining an aesthetically pleasing appearance. This not only enhances the fryer’s longevity but also makes it easy to clean, a critical factor in fast-paced kitchen environments.

Equipped with advanced control systems, the Pitco Frialator VF35 offers precise temperature management, which is essential for achieving perfect frying results. The powerful temperature control mechanisms provide rapid recovery time, maintaining optimal oil temperature even when large quantities of food are added. This feature not only enhances food quality but also boosts overall productivity in the kitchen.

The VF35 incorporates a state-of-the-art oil filtration system that improves the quality of the oil and extends its life, reducing operational costs associated with frequent oil changes. This built-in filtration system can be automated, allowing operators to focus on other kitchen tasks while ensuring the oil remains clean for consistent frying results.

Safety is another critical aspect of the VF35 design. It includes several built-in safety features such as a cool-touch handle for the fry baskets, as well as an emergency shut-off switch, helping to prevent accidents and ensuring operator safety during use. Additionally, the fryer is designed for easy maintenance, allowing quick access to components for servicing, making it a convenient choice for busy establishments.

The Pitco Frialator VF35 not only meets the demands of high volume frying but does so with a focus on efficiency and ease of use. Its combination of durable construction, clever design, cutting-edge technology, and safety features makes it an indispensable asset in any commercial kitchen aiming to deliver exceptional fried foods, all while keeping the operation running smoothly and economically. Whether it’s golden-brown French fries, crispy chicken, or a variety of other fried delicacies, the VF35 is equipped to handle it all with flair and efficiency.