TROUBLESHOOTING

NOTHING WORKS (Control Panel not lit, Blower not working)

Solution 1: Turn on power at circuit breaker panel or fuse box. Check for tripped breaker or blown fuse.

Solution 2: Make sure hood main power switch is on.

LIGHTS NOT TURNING ON

Solution 1: see “nothing works”

Solution 2: Swap out lights to determine if bulbs are defective.

RANGE HOOD VIBRATES WHEN BLOWER IS ON

Solution: Make sure the range hood has been secured properly to the ceiling or wall.

BLOWER SYSTEM SEEMS WEAK

Solution 1: Increase the fan speed, ensure that it is at a high enough setting.

Solution 2: Make sure the ducting is sized correctly. Range hood will not function efficiently with insufficient duct size (IE, 9” duct over 8” hole)

Solution 3: Check to see if duct is clogged or if damper unit (half-circular flapper) is installed incorrectly. A tight mesh on a side wall cap unit might also cause restriction to the air flow.

AIR NOT VENTING OUT PROPERLY

Solution 1: Make sure there is at least 28” (71 cm) between the stove top and the bottom of the hood

Solution 2: Reduce the number of elbows and length of duct work. Check to ensure all joints are properly connected, sealed, and taped.

Solution 3: Make sure power is on high speed for heavy cooking.

Image 18
Contents Proline Proline Customer Support Team Table of Contents Important Safety Notice To reduce the risk of a range top grease fire Wall Hood Control Panel Grease Filters Baffle filterAluminum filter Ductless Filters Charcoal filterVertical Roof Venting Venting OptionsHorizontal Wall Venting OptionVenting Requirements Height & Venting RequirementsTools YOU’LL Need PreparationInspect Range Hood Prepare DuctworkWall Hood Installation Install anchors and screwsInstall ceiling bracket Hang hood and connectInstall chimney Install grease filterCare & Cleaning Cleaning the filterCleaning Exterior Surfaces Removing the filter Replacing the Light BulbTroubleshooting Nothing Works Control Panel not lit, Blower not workingOne Year Warranty Parts Only WarrantyTwo Year Warranty Parts & Labor What is not CoveredReturns Upon Receipt of Your HoodReturns Return Claims not Accepted if ExchangesExchanges Please NoteProline Range Hoods