Kobe Range Hoods IS2136SQB, IS2142SQB Trouble Shooting, Issue Possible Cause Solution

Page 19

TROUBLE SHOOTING

Issue

Possible Cause

Solution

After Installation,

The power is not on.

Make sure the circuit breaker and the unit’s power is

both motors and

 

ON. Use a voltage meter to check the power supply.

lights are not

The wire connection is not secure.

Check and tighten wire connection.

working.

The control panel and processor board

Check wire continuity from control panel to processor

 

wiring are disconnected.

board.

 

The motor transformer is defective.

Check the power input and power output on the

 

 

motor transformer.

 

 

If it’s needed, replace the motor transformer.

 

 

 

 

The control panel and processor board is

Replace the control panel or processor board.

 

defective.

 

Lights are

The motor(s) is defective.

Replace the motor.

working, but

The capacitor(s) is defective.

Replace capacitor(s).

motor(s) is not.

The control panel or processor board is

Replace the control panel or processing board.

 

defective.

 

The range

The blower system is not secure.

Tighten the turbine impeller/squirrel cage and air

hood is

 

chamber.

vibrating.

The turbine impeller/squirrel cage is

Replace the turbine impeller/squirrel cage.

 

not balanced.

 

 

Hood is not secured in place.

Check the installation of hood, tighten the

 

 

mounting bracket.

The motor is

Halogen Light bulb(s) is defective.

Try placing the trouble light bulb(s) to a working

working, but

 

socket, if the bulb(s) still doesn’t work; replace

the lights are

 

the halogen light bulb(s).

not working.

The light wiring(s) is loose.

Check wire continuity from processor board to

 

 

light transformer to halogen light housing(s).

 

Light transformer is defective.

Check power input and power output on the light

 

 

transformer. If it’s needed, replace the light

 

 

transformer.

 

The control panel or processor board is

Replace the control panel or processing board.

 

defective.

 

 

 

 

The range

The range hood is installed outside of

Adjust the clearance between the range hoods

hood is not

the manufacture recommended

and cook top to 27” to 30”. For Island range

venting out

clearance.

hood and professional series range hood, the

correctly.

 

clearance between the range hoods and cook

 

 

top is 30” to 36”.

 

There is no make-up air inside the

Open the window to enhance the performance

 

house.

of the range hood by creating a sufficient make-

 

 

up air.

 

Obstacle blocking the pipe work.

Remove all obstacles from the duct work.

 

 

 

 

The pipe size is smaller than the

Change the ducting according to the

 

suggested pipe size.

manufacture suggestion.

Cold air is

The pipe connection is not properly

Check the pipe installation.

coming into the

sealed.

 

home.

 

 

17

Image 19
Contents Kobe Brand Range Hood English English ContentsTOP Grease Fire Important Safety InstructionsWhat to Do If You Smell Gas What to Do In The Event Of a Range Top Grease FireMust keep all material for returns or refunds Components of PackageCalculation before Installation InstallationPreparation before Installation Wiring to Power Supply Duct Cover Installation Operation Instructions To Clean Hood Surface MaintenanceTo Clean Baffle Filters Replacing Light Bulb Speed SpecificationsMeasurements & Diagrams Description Model /SIZE Parts ListModel NO. IS2136SQB IS2142SQB Circuit Diagram Issue Possible Cause Solution Trouble ShootingClaims will not be Accepted After the Allocated Days DisclaimerConditions WarrantyWarranty Certificate TWO-YEAR Warranty Service PeriodConsequential Damage ServiceImplied WARRANTIES/STATE LAW Register Your Product Product RegistrationRecord the Following Information for Your Record Table DES Matières FrenchConsignes DE Sécurité Importantes Que faire si une odeur de gaz se dégage Que faire en cas dun incendie de graisse sur la cuisinièreBoîte de la hotte de cuisinière Boîte 1 DE 2 Boîte 2 DE Contenu DE L’EMBALLAGEMesures à prendre avant linstallation SVP Lire AU Complet Avant LinstallationPhoto Consigne DE Sécurité Placer les filtres déflecteurs sous la hotte. Voir Photo Mode Demploi Entretien Préventif Remplacement Dune Ampoule Spécifications Dimensions DE LA HotteMesures ET Schémas Nos de modèles IS2136SQB Liste DES PiècesIS2142SQB IS2136SQB Nos de modèlesSchéma DE Câblage Problème Cause probable Solution Avis DE NON-RESPONSABILITÉ Certificat DE Garantie GarantiePériode DE Garantie DE Deux 2 ANS Garanties Tacites / Réglementation Dommages IndirectsEnregistrez votre produit Enregistrement DU ProduitInscrire LES Renseignements Suivants Pour NOS Dossiers Spanish Instrucciones Importantes DE Seguridad Qué Hacer si Siente Olor a Gas PrecauciónCaja de Campana de Extracción Componentes DEL PaqueteCálculo antes de la Instalación InstalaciónFigura Instalación DE LA RED DE Conductos Instalación DE LA Cubierta DE Conductos Instrucciones DE Operación Limpieza de la Superficie de la Campana MantenimientoPara limpiar el Filtro Deflector Para Reemplazar el Foco Velocidad Especific AcionesMedidas Y Diagramas Modelo no IS2136SQB IS2142SQB Listado DE PiezasModelo no IS2136SQB IS2142SQB Diagrama DE Circuito Problema Posible Causa Solución Cláusula DE Exención Condiciones GarantíaCertificado DE Garantía Periodo DE Servicio DE LA Garantía DE DOS AñosGarantías IMPLÍCITAS/LEY Estatal Daños EmergentesServicio Registre su Producto Registro DEL ProductoEscriba LA Siguiente Información Para SUS Archivos Email info@KOBERangeHoods.com