Zanussi ZGF 782 CTN Electrical connections, Supply cable replacement, This HOB Must be Earthed

Page 12

aSeal

FO 0199

Electrical connections

Any electrical work required to install this hob should be carried out by a qualified electrician or competent person, in accordance with the current regulations.

THIS HOB MUST BE EARTHED.

The manufacturer declines any liability should these safety measures not be observed.

This hob is designed to be connected to a 230 V 50 Hz AC electrical supply.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the hob rating plate. The rating plate is located on the bottom of the hob. A copy is attached on the back cover of this book.

The hob is supplied with a 3 core flexible supply cable incorporating a 3amp plug fitted. In the event of having to change the fuse, a 3amp ASTA approved (BS 1362) fuse must be used.

Should the plug need to be replaced for any reason, the wires in the mains lead are coloured in accordance with the following code:

Permanent Connection

In the case of a permanent connection, it is necessary that you install a double pole switch between the hob and the electricity supply (mains), with a minimum gap of 3 mm. between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations.

The switch must not break the yellow and green earth cable at any point.

Ensure that the hob supply cable does not come into contact with surfaces with temperatures higher than 50 deg. C.

Supply cable replacement

The cable used to connect the hob to the electrical supply must comply to the specifications given below.

Min. size Cable/flex

Cable / flex type

Fuse

 

 

 

0.75 mm2

H05 V2V2-F (T90)

3 A

 

 

 

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

)— Connect the green and yellow (earth) wire to the terminal in the plug which is marked with

the letter 'E' or the earth symbol or coloured green and yellow.

Connect the blue (neutral) wire to the terminal in the plug which is marked with the letter 'N' or coloured black.

Connect the brown (live) wire to the terminal in the plug which is marked with the letter 'L' or coloured red.

Upon completion there must be no cut, or stray strands of wire present and the cable clamp must be secure over the outer sheath.

A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely.

FO 0390

12

Image 12
Contents GAS HOB ZGF 782 CTN ZGF 782 CTX Important Safety Information InstallationChild Safety ServiceContents Description of the Hob Using the Wok Stand OperationHob burners Burner Minimum Maximum DiameterMaintenance and Cleaning Hob TopBurners Ignition electrodeSymptom Solution Something Not Working?Cast Iron Pan Supports Instructions for the Installer Engineers technical dataImportant safety requirements Provision for ventilationLocation Installation When the HOB is First InstalledGas Connection Cut Out SizeBuilding Building over a cupboard or drawerBuilding over a kitchen unit with door Fitting the Hob into the worktopSupply cable replacement Electrical connectionsThis HOB Must be Earthed Permanent ConnectionWiring Diagram Fault FindingIgnitor Switch Ignitor Unit Preliminary Electrical Systems CheckIgnition System / Gas Ignition To adjust the gas rate Pressure TestingCommissioning Conversion from Natural Gas to LPGService and Spare Parts Customer CareEuropean guarantee Page Page 35687-7802 11/06