Zanussi ZGF 782 CTX Wiring Diagram, Fault Finding, Preliminary Electrical Systems Check, Yes

Page 13

Wiring Diagram

A. IGNITOR SWITCH

B. IGNITOR UNIT

Fault Finding

Preliminary Electrical Systems Check

PLUG (with cover

SOCKET

removed)

(face view)

Brown Blue

Blue

Brown Green

Yellow

 

Earth Wire

(

)

)

 

Green/Yellow

 

E (

START

 

 

FUSE

 

Isolate appliance

Neutral Wire

 

 

and carry out:

Blue

 

 

 

A: Earth Continuity

 

 

N

L

check.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

YES

Carry out:

 

Carry out:

 

Electricity supply

 

D: Resistance to

 

 

should now be

 

 

 

C: Polarity check.

 

 

 

 

 

 

 

Earth check.

 

satisfactory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Has inlet fuse blown?

NO

YES

Inlet wiring faulty. Rectify any fault.

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fuses as necessary.

A. EARTH CONTINUITY CHECK -Appliance must be electrically disconnected - meter set on Ω (Ohms) x 1 scale and adjust zero if necessary.

a)Test leads from any appliance earth point to earth

pin on plug. Resistance should be less than 0.1 Ω (Ohm), check all earth wires for continuity and all contacts are clean and tight.

B. INSULATION CHECK - Appliance electrically disconnected, all switches ON.

a)meter set on Ω (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on Ω (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component.

It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

13

Image 13
Contents GAS HOB ZGF 782 CTN ZGF 782 CTX Installation Important Safety InformationChild Safety ServiceContents Description of the Hob Operation Using the Wok StandHob burners Burner Minimum Maximum DiameterHob Top Maintenance and CleaningBurners Ignition electrodeSomething Not Working? Symptom SolutionCast Iron Pan Supports Engineers technical data Instructions for the InstallerProvision for ventilation Important safety requirementsLocation When the HOB is First Installed InstallationGas Connection Cut Out SizeBuilding over a cupboard or drawer BuildingBuilding over a kitchen unit with door Fitting the Hob into the worktopElectrical connections Supply cable replacementThis HOB Must be Earthed Permanent ConnectionFault Finding Wiring DiagramIgnitor Switch Ignitor Unit Preliminary Electrical Systems CheckIgnition System / Gas Ignition Pressure Testing To adjust the gas rateCommissioning Conversion from Natural Gas to LPGCustomer Care Service and Spare PartsEuropean guarantee Page Page 35687-7802 11/06