Zanussi ZGF 782 CTN, ZGF 782 CTX manual Instructions for the Installer, Engineers technical data

Page 8

Instructions for the Installer

Engineers technical data

OVERALL DIMENSIONS

Width:

680 mm

Depth:

510 mm

CUT OUT DIMENSIONS

Width:

560 mm

Depth:

480 mm

SUPPLY CONNECTIONS

Gas:

R 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230 V 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Rear Left Burner (semi rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Left Burner (auxiliary)

Heat Input

1.0 kW (3413 BTU/HR)

Rear Right Burner (semi rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Right Burner (rapid)

Heat Input

3.0 kW (10236 BTU/HR)

Central Burner (Ultra-rapid Triple-crown)

Heat Input

4.0 kW (13652 BTU/HR)

TYPE OF

GAS

CHARACTERISTICS

BURNER

 

RAPID

SEMI-RAPID

AUXILIARY

ULTRA-RAPID

 

 

(large)

(medium)

(small)

(triple-crown)

 

 

 

 

 

 

 

 

 

 

POSITION

 

MAX

MIN

MAX

MIN

MAX

MIN

MAX

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

VALUE = 37.78 MJ/m

Ws - 50.7 MJ/ m3

NOMINAL THERMAL

 

 

 

 

 

 

 

 

20 mbar

POWER

kW

3.0

0.65

2.0

0.45

1.0

0.33

4.0

1.2

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

RATE

m3/h

0.286

0.062

0.190

0.043

0.095

0.031

0.381

0.114

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

146

Adjust.

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28-30/37 mbar

VALUE = 49.92 MJ/Kg

NOMINAL THERMAL

 

 

 

 

 

 

 

 

LPG GAS

POWER

kW

2.8

0.65

2.0

0.45

1.0

0.33

4.0

1.2

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

RATE

g/h

202

47

144

32

72

24

288

86

NOZZLE REFERENCE

86

40

71

32

50

28

98

56

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

1/100 mm

 

 

Auxiliary

28

Semi-rapid

32

Rapid

40

Ultra-rapid

56

Aeration adjustment none

APPLIANCE CLASS : 3

APPLIANCE CATEGORY: II2H3+

APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar

8

Image 8
Contents GAS HOB ZGF 782 CTN ZGF 782 CTX Important Safety Information InstallationChild Safety ServiceContents Description of the Hob Using the Wok Stand OperationHob burners Burner Minimum Maximum DiameterMaintenance and Cleaning Hob TopBurners Ignition electrodeCast Iron Pan Supports Symptom SolutionSomething Not Working? Instructions for the Installer Engineers technical dataLocation Important safety requirementsProvision for ventilation Installation When the HOB is First InstalledGas Connection Cut Out SizeBuilding Building over a cupboard or drawerBuilding over a kitchen unit with door Fitting the Hob into the worktopSupply cable replacement Electrical connectionsThis HOB Must be Earthed Permanent ConnectionWiring Diagram Fault FindingIgnitor Switch Ignitor Unit Preliminary Electrical Systems CheckIgnition System / Gas Ignition To adjust the gas rate Pressure TestingCommissioning Conversion from Natural Gas to LPGService and Spare Parts Customer CareEuropean guarantee Page Page 35687-7802 11/06