SPECIFICATIONS

27

SPECIFICATIONS

 

SBVBN(C)

SBVBP(C)

 

30,000 Btu/h

28,000 Btu/h

 

 

 

Gas Type

Natural

Propane/LP

 

 

 

Ignition

Piezo

Piezo

 

 

 

Manifold Pressure

3.5" w.c.

10.0" w.c.

 

 

 

Minimum Inlet Supply Pressure

4.5" w.c.

11.0" w.c.

 

 

 

Thermal Efficiency

70%

70%

 

 

 

Dimension, Inches/mm (HxWxD)

 

 

Stove and Burner System*

27" x 26 1/4" x 20"

27" x 26 1/4" x 20"

 

685.8 x 660.4 x 635mm

685.8 x 660.4 x 635mm

Carton (Insert Only)

23" x 33" x 23"

23" x 33" x 23"

 

584.2 x 838.2 x 584.2mm

584.2 x 838.2 x 584.2mm

 

 

 

Weight, lbs/kg

 

 

Burner System

70 lbs/31.8 kg

70 lbs/31.8 kg

Shipping

75 lbs/34 kg

75 lbs/34 kg

 

 

 

* When installed in Amity cast iron stove body (SCIVFC Series and PSCIVFC Series).

For morevisit www..com

106828-01C

Image 27
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsTo operating burner system Product IdentificationProduct Features PRE-INSTALLATION PreparationLocal Codes Stove Body Assembly Cast Iron Stove and B-VENT Burner System AssemblyAttaching Stove Legs Installing Optional Blower Accessory Installing B-VENT Burner System Into Stove BodyON/OFF Installing Rear CoverInstallation Precautions Venting InstallationInstalling Vent System in a Chase Installation of Listed B-1 VentRelining Systems High Altitude InstallationChecking Vent Capacity ChimneysCauses of Spillage and Corrective Action Troubleshooting Venting ProblemsCast Iron Stove and B-VENT Burner System Installation Flue GAS SpillageInstallation Items Needed Installing GAS Piping to Stove LocationConnecting STOVE/BURNER System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Optional Wall Mount Switch GWMS2 Installing Optional Wall Mounted Thermostat GWMT1Pressure Testing Burner System Gas Connections Installing Battery in Receiver Installing Remote ReceiverREMOVING/REPLACING Glass Door Installing 9-Volt Battery in Hand-Held Remote Control UnitRemove glass door. See Removing/Replacing Glass Door, Installing LOGS, Lava ROCK, and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating Stove with B-VENT Burner SystemOperating Stove with Vent Burner System Optional Remote Thermostat Series OperationON/OFF Series Models Ghrcb and Cghrcb Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Replacement PartsTechnical Service Wiring DiagramSbvbnc Sbvbpc SpecificationsModels Sbvbnc and Sbvbpc Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation Amity SCIVFC* Series PSCIVFC* SeriesIndicates Color Suffix Designation Amity SCIVFC* Series and PSCIVFC* SeriesAccessories Receiver and HAND-HELD Remote Control KIT Ghrcb and CghrcbTHERMOSTATICALLY- Controlled Blower KIT CDA3620TB Owners Registration Form Postage Required 106828-01C Warranty Information

SBVBP(C), SBVBN(C) specifications

Desa SBVBP(C) and SBVBN(C) are two advanced models in the landscape of environmental and energy-efficient technologies. These innovative designs are at the forefront of sustainable construction, showcasing a plethora of features and characteristics that make them stand out.

One of the main features of Desa SBVBP(C) is its emphasis on bioclimatic architecture, which ensures that buildings harmonize with their surrounding environment. This model incorporates passive solar design principles, allowing natural light to penetrate efficiently while minimizing energy loss. High-performance thermal insulation is another significant characteristic, which helps maintain comfortable indoor temperatures regardless of external weather conditions.

Desa SBVBN(C) complements its counterpart with its remarkable integration of renewable energy technologies. Equipped with photovoltaic panels and wind turbine systems, this model harnesses natural energy sources to reduce reliance on non-renewable energy. The energy generated can be used for lighting, heating, and powering appliances, making the building self-sufficient and cost-effective over time.

Both models utilize smart technology for enhanced operational efficiency. Internet of Things (IoT) devices allow for real-time monitoring and control of energy consumption, promoting sustainable living practices among residents. Automated systems adjust lighting, heating, and cooling based on occupancy and time of day, further contributing to energy savings.

Water conservation is another crucial aspect of Desa SBVBP(C) and SBVBN(C). Both designs implement rainwater harvesting systems and greywater recycling technologies, ensuring that water usage is minimized and reused effectively. This not only lowers utility bills for occupants but also contributes to environmental sustainability by reducing the strain on local water resources.

The construction materials used in both models emphasize sustainability, utilizing recycled, locally sourced, and eco-friendly materials whenever possible. This commitment to green building practices ensures that the overall environmental footprint of the structures is minimal.

In summary, Desa SBVBP(C) and SBVBN(C) represent a paradigm shift towards eco-conscious living. Through the integration of advanced technologies, renewable energy sources, and smart systems, these models provide a blueprint for sustainable development that addresses the pressing challenges of climate change and environmental degradation. As cities around the world seek innovative solutions to improve urban living, models like these shine as beacons of hope and progress.