Desa SBVBP(C), SBVBN(C) installation manual Venting Installation, Installation Precautions

Page 9

CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBLY

Installing Rear Cover (Cont.)

VENTING INSTALLATION

Installation Precautions

Type B-Vent Installation

9

CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBLY

Continued

4.Open lower door panel. The valve is attached to the underside of the burner system assembly.

5.Connect one terminal of the wire from ON/OFF switch to the THTP terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 20. If wires are not connected as shown, the ON/OFF switch will not work.

To Control Switch

Figure 20 - Control Valve Terminals

VENTING INSTALLATION

WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage, or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage, or loss of life.

NOTICE: Failure to follow these instructions will void the warranty.

INSTALLATION PRECAUTIONS

Consult local building codes before beginning the installation. Only a qualified service person should install venting system. The in- staller must follow these safety rules:

Wear gloves and safety glasses for protection

Use extreme caution when using ladders or when on roof tops

Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on your venting system:

Installation of any damaged venting component

Unauthorized modification of the venting system

Installation of any component part not manufactured or approved by DESA

Installation other than as instructed by these instructions

Your DESA stove with B-vent burner system is approved for use with any listed gas vent. A listed gas vent is a factory made and listed system designed, and installed exclusively for removing products of combustion, excess air, and dilution air resulting from burning fuel gas. Metal vents, the most common type of vent, employ double wall construction enclosing an insulating air space. This air space both helps keep flue gases warm and reduce heat transferred to nearby combustibles. This appliance is equipped with a safety control system designed to protect against improper venting of combustion products.

It is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust. Certain limitations apply to vent configurations and must be strictly followed.

WARNING: This gas stove with burner system and vent assembly must be vented directly to the outside. The venting system must NEVER be at- tached to a chimney serving a separate solid fuel burning appliance.

TYPE B-VENT INSTALLATION (Listed B-0 or Greater)

Before beginning installation be sure that the overall height and gas vent size conform to building code requirements. Gas vents extending through pitched roofs can extend a minimum height of at least 600 mm (2') higher than any obstruction within 3m (10'). Gas vents extending through flat roofs are required to extend at least 600 mm (2') above the roof and at least 600 mm (2') higher than any portion of the building or adjoining building within 3m (10') of the gas vent.

In absence of local codes, follow Section 7.0 of the current Na- tional Fuel Gas Code NFPA 54/ANSI Z223.1 and the Natural Gas Installation Code - vent sizings for Category I systems us- ing double wall B-1 vent pipe.

Where the gas vent extends through accessible spaces, it should be enclosed to avoid personal contact and damage. Enclosure walls should have a fire rating equal to or greater than the floors through which the gas vent passes except in single or two-fam- ily dwellings.

Situate the gas vent in the structure so that it can be installed without cutting joists, sills, plates, or major load bearing parti- tions or members. It is also important to locate the base of the gas vent as near as possible to the heating appliance.

This burner system must be properly connected to a venting system. This burner system is equipped with a vent safety shutoff system.

Use only vents labeled "FOR EXTERIOR USE" above the roofline.

Consult the authority having jurisdiction to select the correct gas vent diameter. Avoid using a larger than necessary diameter.

For morevisit www..com

106828-01C

Image 9
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsTo operating burner system Product IdentificationProduct Features PRE-INSTALLATION PreparationLocal Codes Stove Body Assembly Cast Iron Stove and B-VENT Burner System AssemblyAttaching Stove Legs Installing Optional Blower Accessory Installing B-VENT Burner System Into Stove BodyON/OFF Installing Rear CoverInstallation Precautions Venting InstallationInstalling Vent System in a Chase Installation of Listed B-1 VentChecking Vent Capacity High Altitude InstallationChimneys Relining SystemsCast Iron Stove and B-VENT Burner System Installation Troubleshooting Venting ProblemsFlue GAS Spillage Causes of Spillage and Corrective ActionInstallation Items Needed Installing GAS Piping to Stove LocationConnecting STOVE/BURNER System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Optional Wall Mount Switch GWMS2 Installing Optional Wall Mounted Thermostat GWMT1Pressure Testing Burner System Gas Connections Installing Battery in Receiver Installing Remote ReceiverREMOVING/REPLACING Glass Door Installing 9-Volt Battery in Hand-Held Remote Control UnitRemove glass door. See Removing/Replacing Glass Door, Installing LOGS, Lava ROCK, and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Stove with B-VENT Burner System Lighting InstructionsOperating Stove with Vent Burner System Optional Remote Thermostat Series OperationON/OFF Series Models Ghrcb and Cghrcb Pilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsWiring Diagram Service HintsSbvbnc Sbvbpc SpecificationsModels Sbvbnc and Sbvbpc Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation Amity SCIVFC* Series PSCIVFC* SeriesIndicates Color Suffix Designation Amity SCIVFC* Series and PSCIVFC* SeriesAccessories Receiver and HAND-HELD Remote Control KIT Ghrcb and CghrcbTHERMOSTATICALLY- Controlled Blower KIT CDA3620TB Owners Registration Form Postage Required 106828-01C Warranty Information

SBVBP(C), SBVBN(C) specifications

Desa SBVBP(C) and SBVBN(C) are two advanced models in the landscape of environmental and energy-efficient technologies. These innovative designs are at the forefront of sustainable construction, showcasing a plethora of features and characteristics that make them stand out.

One of the main features of Desa SBVBP(C) is its emphasis on bioclimatic architecture, which ensures that buildings harmonize with their surrounding environment. This model incorporates passive solar design principles, allowing natural light to penetrate efficiently while minimizing energy loss. High-performance thermal insulation is another significant characteristic, which helps maintain comfortable indoor temperatures regardless of external weather conditions.

Desa SBVBN(C) complements its counterpart with its remarkable integration of renewable energy technologies. Equipped with photovoltaic panels and wind turbine systems, this model harnesses natural energy sources to reduce reliance on non-renewable energy. The energy generated can be used for lighting, heating, and powering appliances, making the building self-sufficient and cost-effective over time.

Both models utilize smart technology for enhanced operational efficiency. Internet of Things (IoT) devices allow for real-time monitoring and control of energy consumption, promoting sustainable living practices among residents. Automated systems adjust lighting, heating, and cooling based on occupancy and time of day, further contributing to energy savings.

Water conservation is another crucial aspect of Desa SBVBP(C) and SBVBN(C). Both designs implement rainwater harvesting systems and greywater recycling technologies, ensuring that water usage is minimized and reused effectively. This not only lowers utility bills for occupants but also contributes to environmental sustainability by reducing the strain on local water resources.

The construction materials used in both models emphasize sustainability, utilizing recycled, locally sourced, and eco-friendly materials whenever possible. This commitment to green building practices ensures that the overall environmental footprint of the structures is minimal.

In summary, Desa SBVBP(C) and SBVBN(C) represent a paradigm shift towards eco-conscious living. Through the integration of advanced technologies, renewable energy sources, and smart systems, these models provide a blueprint for sustainable development that addresses the pressing challenges of climate change and environmental degradation. As cities around the world seek innovative solutions to improve urban living, models like these shine as beacons of hope and progress.