The electrical connections

WARNING: THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should this safety measure not be observed.

If the plug that is fitted to your appliance is not suitable for your socket outlet, it must be cut off and the appropriate plug fitted.

Remove the fuse from the cut off plug.

The cut off plug should then be disposed of to prevent the hazard of shocks in case it should be plugged into a 13amp socket in another part of your home.

Important

The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

If you fit your own plug, the colours of the wires in the mains lead of your appliance may not correspond with the markings identifying the terminals in your plug, proceed as follows:

A replacement cover/carrier must be obtained from your local Zanussi Service Force Centre whose address is listed in the Customer Care Booklet which accompanies your instruction manual.

This appliance complies with the E.E.C. Directive No. 87/308 of 2.6.87 relative to radio interference suppression.

This appliance complies with the following E.E.C. Directives:

-73/23 EEC of 19.2.73 (Low Voltage Directive) and subsequent modifications;

-89/336 EEC of 3.5.89 (Electromagnetic Compatibility Directive) and subsequent modifications.

Please ensure that when the appliance is installed it is easily accessible for the engineer in the event of a breakdown.

GREEN & YELLOW

Fig. 4

13 AMP. FUSE

13 AMP

BROWN

BLUE

D207

CORD CLAMP

Connect the Green and Yellow (earth) wire to the terminal in the plug which is marked with the letter «E» or the earth symbol , or coloured green and yellow.

Connect the blue (neutral) wire to the terminal in the plug which is marked with the letter «N» or coloured black.

Connect the brown (live) wire to the terminal in the plug which is marked with the letter «L» or coloured red.

The plug moulded onto the lead incorporates a fuse.

For replacement, use a 13amp BSI362 fuse. Only

ASTA or BSI approved fuses should be used.

The plug must not be used if the fuse cover/carrier is lost. The cover/carrier is indicated by the coloured insert at the base of the plug.

5

Image 5
Contents Refrigerator Freezer Technical Specifications Contents09/96 Conservation InstallationElectrical connections Door reversibility Your Appliance Operation Thawing Frozen food storageIce making Positioning the door shelvesStarting the appliance Cool check temperature guideEveryday use of the cool check temperature guide Defrosting Health and Safety Guidelines Internal cleaning Maintenance and CleaningExternal cleaning When the appliance is not in useWhat Happens if Something Goes WRONG? Exclusions Zanussi standard guarantee conditionsPeace of Mind for Twelve Months