Hunter Fan 90063, 90064 manual Preventative Maintenance

Page 2

W a r n i n g

TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:

1.Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer at the phone number or address listed in the warranty.

2.Before installing, servicing, or cleaning the unit, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely attach a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhaust- ing of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards,

such as those published by the National Fire Prevention Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities.

6.Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible.

7.Acceptable for use over a bathtub or shower when connected to a GFCI protected branch circuit.

8.Install fan at least 5 feet (1.52 m) above the floor.

9.Never place a switch where it can be reached from a tub or shower.

10.This unit must be grounded.

C A U T I O N

1.For general ventilating use only. Do not use for ventilat- ing hazardous or explosive materials.

2.To avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

3.DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward.

4.Please read specification label on product for further information and requirements.

W a r n i n g

DISCONNECT

ELECTRIC

POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT

PREVENTATIVE MAINTENANCE

A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.

TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.

TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.

METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.

MAINTENANCE

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time.

2

41722-01 3/29/2006

41722_EngS_3.29.03.indd 2

3/29/06 10:54:39 PM

Image 2
Contents Read and Save These Instructions Preventative Maintenance Before Installation X5 aRemove the motor/blower from the housing A11 A12 A16 A14A15 A20 A18A19 A22B13 A23B11 B14B18 B15B17 B19B22 B23 B20B21 B24B28 Existing Construction accessible from aboveB27 C11C15C16 C12C14 C17 C21C25 C22C24 C26C29 C30 Existing Construction accessible only from belowC27 C28 D11D15 D16D20 D17D18 D19D23 D24 Attaching the GrilleTrouble Shooting SolutionWarranty Limited WarrantyDesde Í a S t a l a c i ó nPrecaución Antes de la instalación Verifique todos losSpan3.29.06.indd 29/06 110003 PM Construcción nueva fijación a la viga Tire de los alambres por el aliviador de tensiones Encendido Apagado Vaya al paso En la página 38 para Fijar la rejilla B18 B22 B23C11 Ventilador Existente SIN Ventilador Existente Construcción existente accesible desde arribaRecorte una abertura para el alojamiento Apriete los tornillos del aliviador de tensiones 41722-02 3/29/2006 C29 Construcción existente accesible sólo desde abajoSpan3.29.06.indd 29/06 110035 PM 29/06 110039 PM D23 Fijación de la rejillaSolución de problemas SoluciónGarantía Garantía Limitada