Connect the electrical wires as follows:

3 Connect wires tightly and securely using wire connectors (not supplied).

• Black to Black

• White to White

• Green to Green

Range Hood

Conduit

Wire Connector (not supplied)

Wire (unit side)

Make sure that all wires are connected

4 properly and enclosed inside of the wiring compartment.

Wire (conduit side)

4. FINAL ASSEMBLY AND CHECK

Two 60 W light bulbs (not supplied) can be mounted to this range hood. Prior to final assembly, install light bulbs (halogen or ordinary type, in the base diameter 26 mm), rated 120 V - 60 W or below.

Assembly (refer to “PREPARATION”)

1 (1) Replace the fan case cover with 4 screws.

(2) Replace the Rectifier Baffle Panel with 2 screws.

(3) Install the oil catch tray.

2

Check

(1) Turn on the electrical circuit to the range hood.

(2)Make sure that the switch and light operate correctly. Refer to page 5 of the Operation Manual.

(3)Check the ventilating functions at High ( ), Medium ( ) and Low ( ) positions.

(4)Make sure that the range hood has no abnormal noises and/or vibration.

CAUTION: • To reduce the risk of injury, keep your hands and other objects away from the fan while it is in motion.

• Wear working gloves to avoid injury.

13

Image 12
Contents Installation Manual Model FSR-3000Safety Instructions Page Size & Dimensions AccessoriesName of Parts ModelRange Hood Location Installation Preparation¼ × 10 Vertical Ducting ¼ × 10 Horizontal Ducting Round Vertical Ducting Round Duct Joint Case of 3-1/4×10Vertical Discharge Case of 7 Round Vertical DischargeCase of 3-1/4×10Horizontal Discharge Referring to Size & Dimensions Range Hood MountingConnecting Power Supply Wires Final Assembly and Check Assembly refer to PreparationCheck Circuit Diagram 60Hz1U030381