;In Case of 3-1/4"×10"Vertical Discharge

Mount the supplied 3-1/4"×10" rectangular duct joint on the top plate with 4 screws (2 pieces: removed in Step 4-1, the others: supplied).

Then attach the supplied soft tape around the duct joint.

Soft Tape

Duct Joint

;In Case of 7" Round Vertical Discharge

First, remove half-cut circular part of the top plate (duct knockout) using a hammer, pliers, etc.

Mount the 7" round duct joint removed in step (1) with 4 screws.

Then attach the supplied soft tape around the duct joint.

CAUTION: • Wear working gloves to avoid injury.

Do not apply excessive force when removing the knockout. The fan may be damaged.

;In Case of 3-1/4"×10"Horizontal Discharge

First, remove half-cut rectangular part of the rear plate (duct knockout) using a hammer, pliers, etc. Mount the supplied 3-1/4"×10" rectangular duct joint with 2 screws.

Then attach the supplied soft tape around the duct joint. To close the opening of the top plate, attach the supplied cover plate with 2 screws.

Hit dented points on the circular edge

Duct

Knockout

Hit dented points

on the rectangular edge

Duct

Knockout

Duct Joint

Soft Tape

7" Round

Duct Joint

Insert into the holes

Cover Plate

Engage with the notches

10

Image 9
Contents Model FSR-3000 Installation ManualSafety Instructions Page Accessories Size & DimensionsName of Parts ModelRange Hood Location Installation Preparation¼ × 10 Vertical Ducting ¼ × 10 Horizontal Ducting Round Vertical Ducting Round Duct Joint Case of 3-1/4×10Vertical Discharge Case of 7 Round Vertical DischargeCase of 3-1/4×10Horizontal Discharge Range Hood Mounting Referring to Size & DimensionsConnecting Power Supply Wires Final Assembly and Check Assembly refer to PreparationCheck 60Hz Circuit Diagram1U030381